The Challenge of External Generalisability: Insights from the Bicentric Validation of a [68Ga]Ga-PSMA-11 PET Based Radiomics Signature for Primary Prostate Cancer Characterisation Using Histopathology as Reference

<b>Background</b>: PSMA PET radiomics is a promising tool for primary prostate cancer (PCa) characterisation. However, small single-centre studies and lack of external validation hinder definitive conclusions on the potential of PSMA PET radiomics in the initial workup of PCa. We aimed to validate a radiomics signature in a larger internal cohort and in an external cohort from a separate centre. <b>Methods</b>: One hundred and twenty-seven PCa patients were retrospectively enrolled across two independent hospitals. The first centre (IRCCS San Raffaele Scientific Institute, Centre 1) contributed 62 [<sup>68</sup>Ga]Ga-PSMA-11 PET scans, 20 patients classified as low-grade (ISUP grade < 4), and 42 as high-grade (ISUP grade ≥ 4). The second centre (Stanford University Hospital, Centre 2) provided 65 [<sup>68</sup>Ga]Ga-PSMA-11 PET scans, and 49 low-grade and 16 high-grade patients. A radiomics model previously generated in Centre 1 was tested on the two cohorts separately and afterward on the entire dataset. Then, we evaluated whether the radiomics features selected in the previous investigation could generalise to new data. Several machine learning (ML) models underwent training and testing using 100-fold Monte Carlo cross-validation, independently at both Centre 1 and Centre 2, with a 70-30% train-test split. Additionally, models were trained in one centre and tested in the other, and vice versa. Furthermore, data from both centres were combined for training and testing using Monte Carlo cross-validation. Finally, a new radiomics signature built on this bicentric dataset was proposed. Several performance metrics were computed. <b>Results:</b> The previously generated radiomics signature resulted in an area under the receiver operating characteristic curve (AUC) of 80.4% when tested on Centre 1, while it generalised poorly to Centre 2, where it reached an AUC of 62.7%. When the whole cohort was considered, AUC was 72.5%. Similarly, new ML models trained on the previously selected features yielded, at best, an AUC of 80.9% for Centre 1 and performed at chance for Centre 2 (AUC of 49.3%). A new signature built on this bicentric dataset reached, at best, an average AUC of 91.4% in the test set. <b>Conclusions:</b> The satisfying performance of radiomics models when used in the original development settings, paired with the poor performance otherwise observed, emphasises the need to consider centre-specific factors and dataset characteristics when developing radiomics models. Combining radiomics datasets is a viable strategy to reduce such centre-specific biases, but external validation is still needed.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2024-12-07
DOI
https://doi.org/10.3390/cancers16234103
Citations
5
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Challenge of External Generalisability: Insights from the Bicentric Validation of a [68Ga]Ga-PSMA-11 PET Based Radiomics Signature for Primary Prostate Cancer Characterisation Using Histopathology as Reference

Pejman Ghanouni, Carolina Bezzi, Heying Duan, Maria Picchio et al.
5 citations
Cancers
Radiomics and Machine Learning in Medical Imaging
2.02
article

The Challenge of External Generalisability: Insights from the Bicentric Validation of a [68Ga]Ga-PSMA-11 PET Based Radiomics Signature for Primary Prostate Cancer Characterisation Using Histopathology as Reference

Pejman Ghanouni, Carolina Bezzi, Heying Duan, Maria Picchio, Andrei Iagaru, Tommaso Russo, Guido Davidzon, Francesco De Cobelli, Alberto Briganti, Andreas Markus Loening, Farshad Moradi, Samuele Ghezzo, Giorgio Brembilla, Geoffrey A. Sonn, Philipp Sorgo, Alan Thong, Benjamin Inbeh Chung, Anna Grattagliano, Arturo Chiti, Praveen Gurunath Bharathi, Ana Maria Samanes Gajate, Paola Mapelli
article en
5 citations

Abstract

<b>Background</b>: PSMA PET radiomics is a promising tool for primary prostate cancer (PCa) characterisation. However, small single-centre studies and lack of external validation hinder definitive conclusions on the potential of PSMA PET radiomics in the initial workup of PCa. We aimed to validate a radiomics signature in a larger internal cohort and in an external cohort from a separate centre. <b>Methods</b>: One hundred and twenty-seven PCa patients were retrospectively enrolled across two independent hospitals. The first centre (IRCCS San Raffaele Scientific Institute, Centre 1) contributed 62 [<sup>68</sup>Ga]Ga-PSMA-11 PET scans, 20 patients classified as low-grade (ISUP grade < 4), and 42 as high-grade (ISUP grade ≥ 4). The second centre (Stanford University Hospital, Centre 2) provided 65 [<sup>68</sup>Ga]Ga-PSMA-11 PET scans, and 49 low-grade and 16 high-grade patients. A radiomics model previously generated in Centre 1 was tested on the two cohorts separately and afterward on the entire dataset. Then, we evaluated whether the radiomics features selected in the previous investigation could generalise to new data. Several machine learning (ML) models underwent training and testing using 100-fold Monte Carlo cross-validation, independently at both Centre 1 and Centre 2, with a 70-30% train-test split. Additionally, models were trained in one centre and tested in the other, and vice versa. Furthermore, data from both centres were combined for training and testing using Monte Carlo cross-validation. Finally, a new radiomics signature built on this bicentric dataset was proposed. Several performance metrics were computed. <b>Results:</b> The previously generated radiomics signature resulted in an area under the receiver operating characteristic curve (AUC) of 80.4% when tested on Centre 1, while it generalised poorly to Centre 2, where it reached an AUC of 62.7%. When the whole cohort was considered, AUC was 72.5%. Similarly, new ML models trained on the previously selected features yielded, at best, an AUC of 80.9% for Centre 1 and performed at chance for Centre 2 (AUC of 49.3%). A new signature built on this bicentric dataset reached, at best, an average AUC of 91.4% in the test set. <b>Conclusions:</b> The satisfying performance of radiomics models when used in the original development settings, paired with the poor performance otherwise observed, emphasises the need to consider centre-specific factors and dataset characteristics when developing radiomics models. Combining radiomics datasets is a viable strategy to reduce such centre-specific biases, but external validation is still needed.

CancersVol. 16(23)
Vita-Salute San Raffaele University (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Istituto di Ricovero e Cura a Carattere Scientifico San Raffaele (IT), Stanford University (US)
Ministero della Salute
Openalex Percentile: Top 12%
Radiomics and Machine Learning in Medical Imaging
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.