Evaluation of Soil Moisture Retrievals from a Portable L-Band Microwave Radiometer

A novel Portable L-band radiometer (PoLRa), compatible with tower-, vehicle- and drone-based platforms, can provide gridded soil moisture estimations from a few meters to several hundred meters yet its retrieval accuracy has rarely been examined. This study aims to provide an initial assessment of the performance of PoLRa-derived soil moisture at a spatial resolution of approximately 0.7 m × 0.7 m at a set of sampling pixels in central Illinois, USA. This preliminary evaluation focuses on (1) the consistency of PoLRa-measured brightness temperatures from different viewing directions over the same area and (2) whether PoLRa-derived soil moisture retrievals are within an acceptable accuracy range. As PoLRa shares many aspects of the L-band radiometer onboard NASA’s Soil Moisture Active Passive (SMAP) mission, two SMAP operational algorithms and the conventional dual-channel algorithm (DCA) were applied to calculate volumetric soil moisture from the measured brightness temperatures. The vertically polarized brightness temperatures from the PoLRa are typically more stable than their horizontally polarized counterparts across all four directions. In each test period, the standard deviations of observed dual-polarization brightness temperatures are generally less than 5 K. By comparing PoLRa-based soil moisture retrievals against the simultaneous moisture values obtained by a handheld capacitance probe, the unbiased root mean square error (ubRMSE) and the Pearson correlation coefficient (R) are mostly below 0.05 m3/m3 and above 0.7 for various algorithms adopted here. While SMAP models and the DCA algorithm can derive soil moisture from PoLRa observations, no single algorithm consistently outperforms the others. These findings highlight the significant potential of ground- or drone-based PoLRa measurements as a standalone reference for the calibration and validation of spaceborne L-band synthetic aperture radars and radiometers. The accuracy of PoLRa-yielded high-resolution soil moisture can be further improved via standardized operational procedures and appropriate tau-omega parameters.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2024-12-06
DOI
https://doi.org/10.3390/rs16234596
Citations
4
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Soil Moisture Retrievals from a Portable L-Band Microwave Radiometer

Adam C. Watts, Mohamad Alipour, Elahe Soltanaghai, Derek Houtz et al.
4 citations
Remote Sensing
Soil Moisture and Remote Sensing
0.82
article

Evaluation of Soil Moisture Retrievals from a Portable L-Band Microwave Radiometer

Adam C. Watts, Mohamad Alipour, Elahe Soltanaghai, Derek Houtz, Runze Zhang, Abhi Nayak
article en
4 citations

Abstract

A novel Portable L-band radiometer (PoLRa), compatible with tower-, vehicle- and drone-based platforms, can provide gridded soil moisture estimations from a few meters to several hundred meters yet its retrieval accuracy has rarely been examined. This study aims to provide an initial assessment of the performance of PoLRa-derived soil moisture at a spatial resolution of approximately 0.7 m × 0.7 m at a set of sampling pixels in central Illinois, USA. This preliminary evaluation focuses on (1) the consistency of PoLRa-measured brightness temperatures from different viewing directions over the same area and (2) whether PoLRa-derived soil moisture retrievals are within an acceptable accuracy range. As PoLRa shares many aspects of the L-band radiometer onboard NASA’s Soil Moisture Active Passive (SMAP) mission, two SMAP operational algorithms and the conventional dual-channel algorithm (DCA) were applied to calculate volumetric soil moisture from the measured brightness temperatures. The vertically polarized brightness temperatures from the PoLRa are typically more stable than their horizontally polarized counterparts across all four directions. In each test period, the standard deviations of observed dual-polarization brightness temperatures are generally less than 5 K. By comparing PoLRa-based soil moisture retrievals against the simultaneous moisture values obtained by a handheld capacitance probe, the unbiased root mean square error (ubRMSE) and the Pearson correlation coefficient (R) are mostly below 0.05 m3/m3 and above 0.7 for various algorithms adopted here. While SMAP models and the DCA algorithm can derive soil moisture from PoLRa observations, no single algorithm consistently outperforms the others. These findings highlight the significant potential of ground- or drone-based PoLRa measurements as a standalone reference for the calibration and validation of spaceborne L-band synthetic aperture radars and radiometers. The accuracy of PoLRa-yielded high-resolution soil moisture can be further improved via standardized operational procedures and appropriate tau-omega parameters.

Remote SensingVol. 16(23)
US Forest Service (US), University of Illinois Urbana-Champaign (US), Swiss Federal Institute for Forest, Snow and Landscape Research (CH)
U.S. Department of Agriculture, U.S. Forest Service
Life in Land
Openalex Percentile: Top 29%
Soil Moisture and Remote Sensing
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.