Heat Transfer between a Pool Fire and Water Mist Droplets in a Compartment
Technical constraints and standard regulations rendered the engines more efficient but also more prone to fire.Sound insulation and higher operating temperature have increased the odds of fires.The threat is especially prevalent in public transport buses and coaches because the maintenance time is kept as low as possible.Water mist could be a device to extinguish starting fires, even in a cluttered compartment.In this preliminary paper, the interaction between water mist droplets and a n-heptane pool fire is studied through the influence of the nozzle operating pressure on the flow characteristics, water mist cooling performance and heat flux reduction.
Authors
- Olivier Antoine
- Suhaib Umer Ilyas (ORCID: https://orcid.org/0000-0002-7690-0668)
- Robinet Antonin
- Chetehouna Khaled
- Hamidouche Hamidouche
Institutions
- Laboratoire Pluridisciplinaire de Recherche en Ingénierie des Systèmes, Mécanique et Energétique (FR)
- Centre Inria de l'Université de Lille (FR)
Publication Details
- Journal
- Proceedings of the International Conference on Fluid Flow and Thermal Science, ICFFTS ...
- Published
- 2024-11-01
- DOI
- https://doi.org/10.11159/icffts24.104
- Primary Topic
- Fire dynamics and safety research
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Agence Nationale de la Recherche
- CHIST-ERA