Residual resistance ratio measurement system for Nb3Sn wires extracted from Rutherford cables
• Use of printed circuit board (PCB) for measuring the RRR of strands extracted from Rutherford cables, preserving the geometry. • A bespoke cryocooler-based measurement system capable of measuring many samples in a single cooldown. • Using this system, we routinely measure the RRR of individual intra-strand sections corresponding to both cable edges and broad faces of the cable with high reproducibility. • Important for QC of large productions as well as for smaller research projects. Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.
Authors
- Charlie Sanabria (ORCID: https://orcid.org/0000-0001-5017-5309)
- Michael Naus (ORCID: https://orcid.org/0000-0002-4903-4901)
- J.D. Taylor
- Yan Li (ORCID: https://orcid.org/0000-0002-9402-1093)
- Ian Pong (ORCID: https://orcid.org/0000-0002-8996-4249)
- Scott A. Myers (ORCID: https://orcid.org/0000-0001-7803-1649)
- Jonathan Lee (ORCID: https://orcid.org/0000-0001-9003-8456)
- Heng Pan (ORCID: https://orcid.org/0000-0001-9620-0573)
- Marcos Turqueti (ORCID: https://orcid.org/0000-0002-3892-1353)
- Xiaorong Wang (ORCID: https://orcid.org/0000-0001-7065-8615)
- Algirdas Baskys (ORCID: https://orcid.org/0000-0002-1875-8106)
Institutions
- Lawrence Berkeley National Laboratory (US)
- Wuhou District People's Hospital, Chengdu (CN)
- National High Magnetic Field Laboratory (US)
- Decision Systems (United States) (US)
- European Organization for Nuclear Research (CH)
Publication Details
- Journal
- Cryogenics
- Published
- 2024-12-10
- DOI
- https://doi.org/10.1016/j.cryogenics.2024.104002
- Primary Topic
- Superconducting Materials and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- U.S. Department of Energy
- High Energy Physics