Vacuum Assisted Filtered Salt Sampling Progress
Several different design iterations for a filtered salt sampling technique have been tested in non-radiological molten salts. A piston vacuum assembly was designed and reliably and repeatably used to take salt samples through multiple different porous quartz frit sizes (as small as 5 – 10 µm). This design has been modified slightly and sent into the HFEF hot cell for upcoming testing with used fuel electrorefiner salt.