TRFSA-HQS: Transformer-based MRI Compressed Sensing Network with Frequency Domain Self-Attention

Compressive sensing (CS) can reconstruct undersampled magnetic resonance images, but its iterative optimization process tends to be computationally intensive and time-consuming. Convolutional neural networks (CNNs) have demonstrated impressive reconstruction performance through non-linear feature extraction and mapping capabilities. However, CNNs often struggle to effectively learn and capture global dependencies in the data. Therefore, constructing a MRI reconstruction method that meets clinical real-time imaging and captures dynamic global correlation is crucial in fast and high-precision MRI tasks. We propose a deep unfolding network (TRFSA-HQS) for fast and accurate CS reconstruction, which combines frequency domain self-attention (FSA) based Transformer and half-quadratic splitting (HQS) iterative optimization scheme. TRFSA-HQS adopts an iterative scheme based on HQS to effectively decouple and update optimization problems. The decoupled data subproblems are updated by minimizing the objective function with competitive terms, while the regularization subproblems are updated using the TRFSA deep prior network. The TRFSA module employs an asymmetric UNet architecture, where the encoder and decoder utilize a frequency-domain discriminative feedforward network (DFFN) and FSA. The DFFN selectively extracts deep features from different frequency components, while the FSA captures global dependencies in the frequency domain. The experiment demonstrate that the proposed model achieves an average reconstruction PSNR of 35.11dB on a 0.2 sampling rate test set on FastMRI knee joint data, with an inference time of 0.74s. It has good reconstruction performance and noise robustness, meeting the clinical real-time imaging requirements.

Authors

Publication Details

Journal
Advances in Computer and Engineering Technology Research
Published
2024-12-06
DOI
https://doi.org/10.61935/acetr.4.1.2024.p185
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TRFSA-HQS: Transformer-based MRI Compressed Sensing Network with Frequency Domain Self-Attention

Peng Sun, Jiangtao Li, Taiping Mo, Mingfeng Zheng
Advances in Computer and Engineering Technology Research
Advanced MRI Techniques and Applications
article

TRFSA-HQS: Transformer-based MRI Compressed Sensing Network with Frequency Domain Self-Attention

Peng Sun, Jiangtao Li, Taiping Mo, Mingfeng Zheng
article en

Abstract

Compressive sensing (CS) can reconstruct undersampled magnetic resonance images, but its iterative optimization process tends to be computationally intensive and time-consuming. Convolutional neural networks (CNNs) have demonstrated impressive reconstruction performance through non-linear feature extraction and mapping capabilities. However, CNNs often struggle to effectively learn and capture global dependencies in the data. Therefore, constructing a MRI reconstruction method that meets clinical real-time imaging and captures dynamic global correlation is crucial in fast and high-precision MRI tasks. We propose a deep unfolding network (TRFSA-HQS) for fast and accurate CS reconstruction, which combines frequency domain self-attention (FSA) based Transformer and half-quadratic splitting (HQS) iterative optimization scheme. TRFSA-HQS adopts an iterative scheme based on HQS to effectively decouple and update optimization problems. The decoupled data subproblems are updated by minimizing the objective function with competitive terms, while the regularization subproblems are updated using the TRFSA deep prior network. The TRFSA module employs an asymmetric UNet architecture, where the encoder and decoder utilize a frequency-domain discriminative feedforward network (DFFN) and FSA. The DFFN selectively extracts deep features from different frequency components, while the FSA captures global dependencies in the frequency domain. The experiment demonstrate that the proposed model achieves an average reconstruction PSNR of 35.11dB on a 0.2 sampling rate test set on FastMRI knee joint data, with an inference time of 0.74s. It has good reconstruction performance and noise robustness, meeting the clinical real-time imaging requirements.

Advances in Computer and Engineering Technology ResearchVol. 1(4)
Reduced inequalities
Openalex Percentile: Top 61%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.