Seismic Performance Analysis of Full-Frame-Supported Thick Slab Transfer Plate Structure with Skewed Grids Design Above Metro Depot

The full-frame thick slab transfer plate structure enables a skewed grids design between superstructure and substructure, maximizing the architectural potential of the space above and gaining significant attention in engineering. However, its application is recent, and seismic performance analysis for skewed grids designs is lacking. This study investigates a residential building with a thick slab transfer plate structure above metro depot. Due to the complex force transfer mechanism, a 1/40 scale seismic shaking table test was conducted to study the dynamic characteristics and responses under 7 to 8-degree seismic conditions. Numerical simulations were also performed to verify the test results. Findings indicate that after a 7-degree rare earthquake, all dynamic indicators remained within safe limits, showing good seismic performance. Under an 8-degree rare earthquake, the first natural frequency decreased by 27.93%, causing some damage mainly in the upper tower, while the thick slab transfer plate structure remained undamaged. This aligns with the expected “strong transfer floor, weak tower” failure mechanism.

Authors

Publication Details

Journal
Industrial Construction
Published
2024-11-01
DOI
https://doi.org/10.3724/j.gyjzg24073005
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Performance Analysis of Full-Frame-Supported Thick Slab Transfer Plate Structure with Skewed Grids Design Above Metro Depot

Xin Qi, Shan Gao, Hongbo Liu, Peng Du et al.
Industrial Construction
Structural Behavior of Reinforced Concrete
article

Seismic Performance Analysis of Full-Frame-Supported Thick Slab Transfer Plate Structure with Skewed Grids Design Above Metro Depot

Xin Qi, Shan Gao, Hongbo Liu, Peng Du, Sinan JING
article en

Abstract

The full-frame thick slab transfer plate structure enables a skewed grids design between superstructure and substructure, maximizing the architectural potential of the space above and gaining significant attention in engineering. However, its application is recent, and seismic performance analysis for skewed grids designs is lacking. This study investigates a residential building with a thick slab transfer plate structure above metro depot. Due to the complex force transfer mechanism, a 1/40 scale seismic shaking table test was conducted to study the dynamic characteristics and responses under 7 to 8-degree seismic conditions. Numerical simulations were also performed to verify the test results. Findings indicate that after a 7-degree rare earthquake, all dynamic indicators remained within safe limits, showing good seismic performance. Under an 8-degree rare earthquake, the first natural frequency decreased by 27.93%, causing some damage mainly in the upper tower, while the thick slab transfer plate structure remained undamaged. This aligns with the expected “strong transfer floor, weak tower” failure mechanism.

Industrial ConstructionVol. 54(11)
Sustainable cities and communities
Openalex Percentile: Top 76%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic Performance Analysis of Full-Frame-Supported Thick Slab Transfer Plate Structure with Skewed Grids Design Above Metro Depot — Xin Qi, Shan Gao, et al. · Industrial Construction (2024) | TGRS Research Map | TGRS