The impact of surface polarisation on the degradation of tunnel oxide passivating contacts in silicon solar cells

Tunnelling oxide passivating contact (TOPCon) silicon solar cells have risen to the mainstream in photovoltaic energy deployment worldwide. Enhancing the reliability and longevity of TOPCon solar modules will ensure the continuous growth of solar power on a multi-terawatt scale. This work investigates the mechanisms involved in surface-related degradation (SRD) in TOPCon passivating schemes, specifically focusing on two aspects. Firstly, TOPCon contacts can exhibit firing-induced instabilities that correlate with increased recombination from degradation in surface passivation. Secondly, we explored the influence of surface polarisation, induced by corona charging, on SRD by subjecting samples to various light soaking and annealing conditions. The results demonstrate that the presence of an electric field at the surface accelerates SRD, particularly under positive corona charge conditions. Effective lifetimes on symmetrical TOPCon specimens were significantly reduced and correlated to surface passivation degradation under positive polarisation. The degradation observed supports previous findings where charged hydrogen ions, which respond readily to electric fields, play a critical role in the observed degradation. This study contributes to the body of evidence aimed at understanding hydrogen kinetics at the SiO x /c-Si interface, providing valuable insights into the mechanisms driving SRD in TOPCon solar cells, with implications for enhancing the stability and performance of silicon solar panels. • Surface polarisation accelerates degradation in TOPCon solar cells. • Positive surface charge significantly reduces TOPCon lifetime performance. • Hydrogen ions migrate under electric fields, causing Surface-Related-Degradation (SRD). • SRD impacts TOPCon solar cell stability and efficiency.

Authors

Institutions

Publication Details

Journal
Solar Energy Materials and Solar Cells
Published
2024-12-07
DOI
https://doi.org/10.1016/j.solmat.2024.113340
Citations
2
Primary Topic
Silicon and Solar Cell Technologies
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of surface polarisation on the degradation of tunnel oxide passivating contacts in silicon solar cells

P.P. Altermatt, Donghao Liu, Brendan Wright, Phillip Hamer et al.
2 citations
Solar Energy Materials and Solar Cells
Silicon and Solar Cell Technologies
0.42
article

The impact of surface polarisation on the degradation of tunnel oxide passivating contacts in silicon solar cells

P.P. Altermatt, Donghao Liu, Brendan Wright, Phillip Hamer, Ruy S. Bonilla, Matthew Wright
article en
2 citations

Abstract

Tunnelling oxide passivating contact (TOPCon) silicon solar cells have risen to the mainstream in photovoltaic energy deployment worldwide. Enhancing the reliability and longevity of TOPCon solar modules will ensure the continuous growth of solar power on a multi-terawatt scale. This work investigates the mechanisms involved in surface-related degradation (SRD) in TOPCon passivating schemes, specifically focusing on two aspects. Firstly, TOPCon contacts can exhibit firing-induced instabilities that correlate with increased recombination from degradation in surface passivation. Secondly, we explored the influence of surface polarisation, induced by corona charging, on SRD by subjecting samples to various light soaking and annealing conditions. The results demonstrate that the presence of an electric field at the surface accelerates SRD, particularly under positive corona charge conditions. Effective lifetimes on symmetrical TOPCon specimens were significantly reduced and correlated to surface passivation degradation under positive polarisation. The degradation observed supports previous findings where charged hydrogen ions, which respond readily to electric fields, play a critical role in the observed degradation. This study contributes to the body of evidence aimed at understanding hydrogen kinetics at the SiO x /c-Si interface, providing valuable insights into the mechanisms driving SRD in TOPCon solar cells, with implications for enhancing the stability and performance of silicon solar panels. • Surface polarisation accelerates degradation in TOPCon solar cells. • Positive surface charge significantly reduces TOPCon lifetime performance. • Hydrogen ions migrate under electric fields, causing Surface-Related-Degradation (SRD). • SRD impacts TOPCon solar cell stability and efficiency.

Solar Energy Materials and Solar CellsVol. 282
UNSW Sydney (AU), University of Oxford (GB)
Royal Academy of Engineering, Engineering and Physical Sciences Research Council, John Fell Fund, University of Oxford
Openalex Percentile: Top 36%
Silicon and Solar Cell Technologies
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.