Temporally resolved concentration profiling via computationally limited, distributed sensor nodes
Abstract Accurate mapping of chemical concentrations in reactor networks remains an obstacle to establish complete systems‐level insight and control. This issue extends beyond traditional reactor design to biological and other inaccessible systems of interest. Recent developments in novel materials with non‐volatile memory allow autonomous sensor nodes to record information with minimal external supervision. Integrating these materials in solution suspended particles demonstrates the unique potential for diffuse measurements of chemical data at the microscale. In this study, we establish a generalized workflow for the simulated deployment of time aware particle sensors (TAPS) in ideal reactor systems to measure analyte profiles, using Gillespie kinetic Monte Carlo algorithms (KMC). Our results show that computationally‐limited, chemically sensitive tracer particles capable of timestamping an analyte detection event can provide accurate analyte profiles throughout multistage reactors in an ensemble fashion.
Authors
- Albert Tianxiang Liu (ORCID: https://orcid.org/0000-0001-8854-5854)
- Matthew Lee Manion
- Joshua Doctor
Institutions
- University of Michigan (US)
Publication Details
- Journal
- AIChE Journal
- Published
- 2024-12-07
- DOI
- https://doi.org/10.1002/aic.18691
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Science Foundation
- American Chemical Society Petroleum Research Fund