Study of the application prospects of film detectors for estimation of α-radiation density

The aim of this research is to study the prospects of using the proposed methods of optical UV spectroscopy and X-ray diffractometry to determine the radiation density of the daughter products of radon decay - α-particles recorded using polymer track detectors. This paper presents the results of experiments on detecting the daughter products of radon decay - α-particles in a room on various floors for a fairly long time (within 6 months), the choice of which made it possible to determine not only the concentration dependences (growth in the density of registered α-particles) over time, but also to determine the lower limit for recording changes in the optical spectra of film detectors used to register α-particles. During the experiments, good convergence of the results of structural changes determined by optical spectroscopy and X-ray diffraction methods was established. These changes are caused by the processes of interaction of α-particles with a polymer detector, characterized by deformation distortion of the molecular chains of the polymer, leading to the formation of defects that affect changes in optical and electron density. The proposed methods were used to determine the connection between the interaction processes of α-particles with the molecular structure of polymer films used as detectors. It was determined that the most significant changes are observed at densities of registered α-particles above 10 4 cm -2 , the value of which is the threshold value for identification of radon decay products using film detectors without chemical etching. • Detection of alpha particles - products of radon decay using polymer detectors • Estimation results of the fundamental absorption edge shift depending on the location of film detectors • Results of the optical transmission spectra of the studied film detectors depending on the exposure time • Using UV spectroscopy and X-ray diffraction methods to detect α particles • The density of latent tracks depending on the exposure time

Authors

Institutions

Publication Details

Journal
Optical Materials X
Published
2024-12-07
DOI
https://doi.org/10.1016/j.omx.2024.100388
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the application prospects of film detectors for estimation of α-radiation density

D. Yerimbetova, Аrtem L. Kozlovskiy, Marina Koņuhova, Umitali N. Tuichiyev
Optical Materials X
Radioactivity and Radon Measurements
article

Study of the application prospects of film detectors for estimation of α-radiation density

D. Yerimbetova, Аrtem L. Kozlovskiy, Marina Koņuhova, Umitali N. Tuichiyev
article en

Abstract

The aim of this research is to study the prospects of using the proposed methods of optical UV spectroscopy and X-ray diffractometry to determine the radiation density of the daughter products of radon decay - α-particles recorded using polymer track detectors. This paper presents the results of experiments on detecting the daughter products of radon decay - α-particles in a room on various floors for a fairly long time (within 6 months), the choice of which made it possible to determine not only the concentration dependences (growth in the density of registered α-particles) over time, but also to determine the lower limit for recording changes in the optical spectra of film detectors used to register α-particles. During the experiments, good convergence of the results of structural changes determined by optical spectroscopy and X-ray diffraction methods was established. These changes are caused by the processes of interaction of α-particles with a polymer detector, characterized by deformation distortion of the molecular chains of the polymer, leading to the formation of defects that affect changes in optical and electron density. The proposed methods were used to determine the connection between the interaction processes of α-particles with the molecular structure of polymer films used as detectors. It was determined that the most significant changes are observed at densities of registered α-particles above 10 4 cm -2 , the value of which is the threshold value for identification of radon decay products using film detectors without chemical etching. • Detection of alpha particles - products of radon decay using polymer detectors • Estimation results of the fundamental absorption edge shift depending on the location of film detectors • Results of the optical transmission spectra of the studied film detectors depending on the exposure time • Using UV spectroscopy and X-ray diffraction methods to detect α particles • The density of latent tracks depending on the exposure time

Optical Materials XVol. 25
L. N. Gumilyov Eurasian National University (KZ), Solid State Physics Laboratory (IN), National Nuclear Center of the Republic of Kazakhstan (KZ), Astana Medical University (KZ), Institute of Solid State Physics (CN), University of Latvia (LV)
Openalex Percentile: Top 66%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.