Flexible Nanostructured NiS-Based Electrochemical Biosensor for Simultaneous Detection of DNA Nucleobases
Herein, we demonstrate a one-step, scalable, solution-processed method for the growth of nickel sulfide (NiS) nanostructures using single-source precursors (SSPs) on a flexible substrate as a versatile framework for simultaneous detection of four DNA nucleobases. The as-grown NiS nanostructures exhibit a broad bandgap range and spherical morphology with high surface area and significant porosity, as confirmed by SEM, TEM, and BET surface area analysis. Consequently, the NiS/Ni-foam electrode exhibited remarkable electrochemical performance toward the oxidation of A, G, T, and C due to its large surface area, high electrode activity, and efficient electron transfer capacity. Under the optimum conditions, the electrode demonstrated selective and simultaneous detection of all four nucleobases over a wide linear range from 200 to 1000 μM for A and G, and 50 to 500 μM for T and C, with a low limit of detection of 159 μM for A, 147.6 μM for G, 16.8 μM for T, and 45.9 μM for C, along with high sensitivity of 1.2 × 10<sup>-4</sup> A M<sup>-1</sup> for A, 6.1 × 10<sup>-4</sup> A M<sup>-1</sup> for G, 1.2 × 10<sup>-3</sup> A M<sup>-1</sup> for T, and 3.0 × 10<sup>-4</sup> A M<sup>-1</sup> for C. The as-fabricated electrode revealed excellent reproducibility and stability toward nucleobase detection and demonstrated a reliable DPV response under different bending and twisting conditions. For immediate practical application, NiS/Ni-foam was utilized to quantify the concentration of all nucleobases in calf thymus and <i>Escherichia coli</i> (<i>E. coli</i>) DNA, resulting in a (G + C)/(A + T) ratio of 0.79 and 1.10, respectively. This simple, cost-effective, and flexible NiS/Ni-foam electrode paves the way for the development of non-invasive, wearable biosensors for potential applications in early disease detection.
Authors
- Chitra Gurnani (ORCID: https://orcid.org/0000-0003-2950-7393)
- Prajakta Gaikwad (ORCID: https://orcid.org/0009-0006-8485-2295)
- Trishala R. Desai (ORCID: https://orcid.org/0000-0003-4286-0810)
- Souradyuti Ghosh (ORCID: https://orcid.org/0000-0002-8510-1171)
Institutions
- Mahindra Group (India) (IN)
- Mahindra University (IN)
Publication Details
- Journal
- ACS Omega
- Published
- 2024-12-07
- DOI
- https://doi.org/10.1021/acsomega.4c07106
- Citations
- 4
- Primary Topic
- Advanced biosensing and bioanalysis techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.94