Improving Femoral Torsion Evaluation in Infants Through Analysis of Variability and Reliability in Two-Dimensional and Three-Dimensional Imaging Measurements of the Femoral Neck Axis

Abstract The femoral neck axis serves as a critical parameter in evaluating hip joint health, particularly in the pediatric population. Commonly used metrics for evaluating femoral torsion, such as the femoral neck-shaft and femoral anteversion angles, rely heavily on precise definitions of the position and orientation of the femoral neck axis. Current measurement methods employing radiographs and performing two-dimensional (2D) measurements on computed tomography (CT) scans are susceptible to errors due to their reliance on reader experience and the inherent limitations in 2D measurements. We hypothesized that utilizing volumetric data would mitigate these errors and enable more accurate and reproducible measurements of the femoral neck axis using the femoral anteversion and femoral neck-shaft angles. To test this hypothesis, we analyzed a historical collection of postmortem infant femoral and pelvic bones (28 hips) aged 0 to 6.5 months, with an average estimated age of 4.68 ± 1.80 months. Our findings revealed an average neck-shaft angle of 128.00 ± 4.92 deg and femoral anteversion angle of 35.56 ± 11.68 deg across all femurs, consistent with literature values. These measurements obtained from volumetric image data were found to be repeatable and reliable compared to conventional methods. Our study suggests that the proposed methodology offers a standardized approach for obtaining repeatable and reproducible measurements, thus potentially enhancing diagnostic accuracy and clinical decision-making in assessing hip developmental conditions in pediatric patients.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Science in Medical Diagnostics and Therapy
Published
2024-12-07
DOI
https://doi.org/10.1115/1.4067358
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Femoral Torsion Evaluation in Infants Through Analysis of Variability and Reliability in Two-Dimensional and Three-Dimensional Imaging Measurements of the Femoral Neck Axis

Andrew E. Anderson, T.J. Chambers, Victor Huayamave, Victoria Melendez
Journal of Engineering and Science in Medical Diagnostics and Therapy
Hip disorders and treatments
article

Improving Femoral Torsion Evaluation in Infants Through Analysis of Variability and Reliability in Two-Dimensional and Three-Dimensional Imaging Measurements of the Femoral Neck Axis

Andrew E. Anderson, T.J. Chambers, Victor Huayamave, Victoria Melendez
article en

Abstract

Abstract The femoral neck axis serves as a critical parameter in evaluating hip joint health, particularly in the pediatric population. Commonly used metrics for evaluating femoral torsion, such as the femoral neck-shaft and femoral anteversion angles, rely heavily on precise definitions of the position and orientation of the femoral neck axis. Current measurement methods employing radiographs and performing two-dimensional (2D) measurements on computed tomography (CT) scans are susceptible to errors due to their reliance on reader experience and the inherent limitations in 2D measurements. We hypothesized that utilizing volumetric data would mitigate these errors and enable more accurate and reproducible measurements of the femoral neck axis using the femoral anteversion and femoral neck-shaft angles. To test this hypothesis, we analyzed a historical collection of postmortem infant femoral and pelvic bones (28 hips) aged 0 to 6.5 months, with an average estimated age of 4.68 ± 1.80 months. Our findings revealed an average neck-shaft angle of 128.00 ± 4.92 deg and femoral anteversion angle of 35.56 ± 11.68 deg across all femurs, consistent with literature values. These measurements obtained from volumetric image data were found to be repeatable and reliable compared to conventional methods. Our study suggests that the proposed methodology offers a standardized approach for obtaining repeatable and reproducible measurements, thus potentially enhancing diagnostic accuracy and clinical decision-making in assessing hip developmental conditions in pediatric patients.

Journal of Engineering and Science in Medical Diagnostics and TherapyVol. 8(3)
University of Utah (US), Embry–Riddle Aeronautical University (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 58%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.