Numerical Investigations on the Start-Up Characteristics and Heat Transfer Performance of a Single-Loop Oscillating Heat Pipe With Different Surface Wettable Vertical Tubes

Abstract The heat transfer performance of an oscillating heat pipe (OHP) was significantly enhanced by changing the inner wall surface wettability and filling ratios. Among the various wettability types, a hybrid surface, where the evaporator and condenser have different wettability, has shown enhancement of heat transfer performance significantly. The effects of different surface wettable vertical tubes are yet to be investigated. Therefore, in this study, a single-loop OHP with three different surface wettable vertical tubes, namely, alternate wettability OHP (AWOHP) were numerically investigated at different filling ratios of 30–90%. The different wettability rates of two vertical tubes caused an uneven distribution of slugs and plugs, which generated an unbalanced pressure difference between the tubes, thereby reducing the start-up time by 60–79%. The bulk mean temperature of the left and right adiabatic tubes was investigated to understand the nature of fluid flow. For filling ratios (FRs) of 30–70%, the right tube temperature was always higher than the left tube in AWOHP 3 (hydrophilic left tube, super-hydrophobic right tube), indicating unidirectional circulatory flow, with an occasional change in direction at 70% FR. At lower FR of 30%, AWOHP 2 (super-hydrophilic left tube, super-hydrophobic right tube) exhibited the highest heat transfer performance. In contrast, at higher FRs of 50–90%, AWOHP 3 exhibited the highest heat transfer performance with conductance (G) of 1075 W/m2 K at an FR of 70%, 55% higher than conventional oscillating heat pipe (COHP).

Authors

Institutions

Publication Details

Journal
ASME Journal of Heat and Mass Transfer
Published
2024-12-07
DOI
https://doi.org/10.1115/1.4067340
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigations on the Start-Up Characteristics and Heat Transfer Performance of a Single-Loop Oscillating Heat Pipe With Different Surface Wettable Vertical Tubes

Kiran Kumar Kupireddi, V. P. Chandramohan, Raghuvaran Chinchedu
1 citations
ASME Journal of Heat and Mass Transfer
Heat Transfer and Boiling Studies
0.21
article

Numerical Investigations on the Start-Up Characteristics and Heat Transfer Performance of a Single-Loop Oscillating Heat Pipe With Different Surface Wettable Vertical Tubes

Kiran Kumar Kupireddi, V. P. Chandramohan, Raghuvaran Chinchedu
article en
1 citations

Abstract

Abstract The heat transfer performance of an oscillating heat pipe (OHP) was significantly enhanced by changing the inner wall surface wettability and filling ratios. Among the various wettability types, a hybrid surface, where the evaporator and condenser have different wettability, has shown enhancement of heat transfer performance significantly. The effects of different surface wettable vertical tubes are yet to be investigated. Therefore, in this study, a single-loop OHP with three different surface wettable vertical tubes, namely, alternate wettability OHP (AWOHP) were numerically investigated at different filling ratios of 30–90%. The different wettability rates of two vertical tubes caused an uneven distribution of slugs and plugs, which generated an unbalanced pressure difference between the tubes, thereby reducing the start-up time by 60–79%. The bulk mean temperature of the left and right adiabatic tubes was investigated to understand the nature of fluid flow. For filling ratios (FRs) of 30–70%, the right tube temperature was always higher than the left tube in AWOHP 3 (hydrophilic left tube, super-hydrophobic right tube), indicating unidirectional circulatory flow, with an occasional change in direction at 70% FR. At lower FR of 30%, AWOHP 2 (super-hydrophilic left tube, super-hydrophobic right tube) exhibited the highest heat transfer performance. In contrast, at higher FRs of 50–90%, AWOHP 3 exhibited the highest heat transfer performance with conductance (G) of 1075 W/m2 K at an FR of 70%, 55% higher than conventional oscillating heat pipe (COHP).

ASME Journal of Heat and Mass TransferVol. 147(5)
National Institute of Technology Warangal (IN)
Openalex Percentile: Top 49%
Heat Transfer and Boiling Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.