StraightTrack: Towards mixed reality navigation system for percutaneous K‐wire insertion

In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire. To ensure accurate feedback, StraightTrack, an MR navigation system designed for percutaneous wire placement in complex anatomy, is introduced. StraightTrack features a marker body equipped with a rigid access cannula that mitigates wire bending due to interactions with soft tissue and a covered bony surface. Integrated with an optical see-through head-mounted display capable of tracking the cannula body, StraightTrack offers real-time 3D visualization and guidance without external trackers, which are prone to losing line-of-sight. In phantom experiments with two experienced orthopedic surgeons, StraightTrack improves wire placement accuracy, achieving the ideal trajectory within <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>5.26</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.29</mml:mn></mml:mrow> </mml:mrow> </mml:math> mm and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>2.88</mml:mn> <mml:mo>±</mml:mo> <mml:mn>1.49</mml:mn></mml:mrow> </mml:mrow> </mml:math> , compared to over 12.08 mm and 4.07 for comparable methods. As MR navigation systems continue to mature, StraightTrack realizes their potential for internal fracture fixation and other percutaneous orthopedic procedures.

Authors

Institutions

Publication Details

Journal
Healthcare Technology Letters
Published
2024-12-01
DOI
https://doi.org/10.1049/htl2.12103
Citations
2
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

StraightTrack: Towards mixed reality navigation system for percutaneous K‐wire insertion

Benjamin D. Killeen, Han Zhang, Greg Osgood, Alejandro Martin‐Gomez et al.
2 citations
Healthcare Technology Letters
Pelvic and Acetabular Injuries
1.15
article

StraightTrack: Towards mixed reality navigation system for percutaneous K‐wire insertion

Benjamin D. Killeen, Han Zhang, Greg Osgood, Alejandro Martin‐Gomez, You Jin Ku, Mingxu Liu, Mathias Unberath, Yang Yue, Taylor, Suxi Gu, Yuxuan Zhao, Lalithkumar Seenivasan
article en
2 citations

Abstract

In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire. To ensure accurate feedback, StraightTrack, an MR navigation system designed for percutaneous wire placement in complex anatomy, is introduced. StraightTrack features a marker body equipped with a rigid access cannula that mitigates wire bending due to interactions with soft tissue and a covered bony surface. Integrated with an optical see-through head-mounted display capable of tracking the cannula body, StraightTrack offers real-time 3D visualization and guidance without external trackers, which are prone to losing line-of-sight. In phantom experiments with two experienced orthopedic surgeons, StraightTrack improves wire placement accuracy, achieving the ideal trajectory within <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>5.26</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.29</mml:mn></mml:mrow> </mml:mrow> </mml:math> mm and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mrow><mml:mn>2.88</mml:mn> <mml:mo>±</mml:mo> <mml:mn>1.49</mml:mn></mml:mrow> </mml:mrow> </mml:math> , compared to over 12.08 mm and 4.07 for comparable methods. As MR navigation systems continue to mature, StraightTrack realizes their potential for internal fracture fixation and other percutaneous orthopedic procedures.

Healthcare Technology LettersVol. 11(6)
Johns Hopkins University (US), Johns Hopkins Medicine (US)
National Science Foundation, Johns Hopkins University
Openalex Percentile: Top 19%
Pelvic and Acetabular Injuries
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.