RANCANG BANGUN PRODUK SUBSTITUSI SISTEM DATA LOGGER ALIRAN DAN TEKANAN AIR PADA ALIRAN PIPA TERTUTUP MENGGUNAKAN KOMUNIKASI LoRaWAN

The availability of data loggers as data acquisition is still limited to sensor levels and the data loggers have not been produced in Indonesia. This makes it difficult for monitors to obtain data such as water pressure and water discharge data. The solution to this problem is to reduce the import cost of purchasing data loggers from abroad by developing data loggers that are able to take data on water level, water pressure. This study aims to determine how the design and performance of data logger system substitution products flow and water pressure using LoRa WAN communication. The test results show that the Water Flow and Pressure Data logger System functions according to the design that has been made with error readings from the itron cyble sensor of ?? and a pressure sensor reading error of 20.66%. The Packet Loss value of sending data from the data logger device is directly proportional to the distance where the smallest packet loss value is 13% at a distance of 50m and 80% at a distance of 2800m.

Authors

Publication Details

Journal
JTT (Jurnal Teknologi Terapan)
Published
2024-10-01
DOI
https://doi.org/10.31884/jtt.v10i2.624
Primary Topic
Decision Support System Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RANCANG BANGUN PRODUK SUBSTITUSI SISTEM DATA LOGGER ALIRAN DAN TEKANAN AIR PADA ALIRAN PIPA TERTUTUP MENGGUNAKAN KOMUNIKASI LoRaWAN

Sarosa Castrena Abadi, Abdur Rohman Harits Martawireja, Sandy Bhawana Mulia, Hadi Supriyanto et al.
JTT (Jurnal Teknologi Terapan)
Decision Support System Applications
article

RANCANG BANGUN PRODUK SUBSTITUSI SISTEM DATA LOGGER ALIRAN DAN TEKANAN AIR PADA ALIRAN PIPA TERTUTUP MENGGUNAKAN KOMUNIKASI LoRaWAN

Sarosa Castrena Abadi, Abdur Rohman Harits Martawireja, Sandy Bhawana Mulia, Hadi Supriyanto, Naufaldo Naufaldo, Wisnu Aji, Wahyu Adhi Candra, Rizki Aji Pratama, Reka Adi
article en

Abstract

The availability of data loggers as data acquisition is still limited to sensor levels and the data loggers have not been produced in Indonesia. This makes it difficult for monitors to obtain data such as water pressure and water discharge data. The solution to this problem is to reduce the import cost of purchasing data loggers from abroad by developing data loggers that are able to take data on water level, water pressure. This study aims to determine how the design and performance of data logger system substitution products flow and water pressure using LoRa WAN communication. The test results show that the Water Flow and Pressure Data logger System functions according to the design that has been made with error readings from the itron cyble sensor of ?? and a pressure sensor reading error of 20.66%. The Packet Loss value of sending data from the data logger device is directly proportional to the distance where the smallest packet loss value is 13% at a distance of 50m and 80% at a distance of 2800m.

JTT (Jurnal Teknologi Terapan)Vol. 10(2)
Openalex Percentile: Top 65%
Decision Support System Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.