Preparation of B <sub>4</sub>C/CS/SiO <sub>2</sub> coating on SS316L for bone implants: Tribological, biological, and antibacterial properties

To improve the wear and corrosion resistance, bioactivity, and antimicrobial properties of 316L stainless steel in clinical environment, three kind of composite coatings of B<sub>4</sub>C, B<sub>4</sub>C/CS, and B<sub>4</sub>C/CS/SiO<sub>2 </sub>were designed and deposited by liquid spraying, respectively. The sliding wear results showed that the B<sub>4</sub>C/CS/SiO<sub>2 </sub>coating improves the surface quality under the synergistic effects of boron carbide, chitosan, and silica, and significantly reduces friction coefficients and wear rates. The friction shear force of the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating increases due to its high hardness and elastic modulus, resulting in a high friction coefficient. However, its high hardness and dense internal structure contributes to wear reduction. Friction experiments under simulated body fluid demonstrate that friction coefficient is reduced by calcium and phosphorus. Electrochemical experiments reveal that all three composite coatings significantly reduce the corrosion rate, and the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating exhibits the best anti-corrosion performance. The vitro mineralization and cell culture experiments demonstrate that the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating has excellent cell proliferation and osteogenic properties, which are attributed to its improved hydrophilicity, increased roughness, and stimulation from Si<sup>4+</sup>. The antibacterial experiments show that the B<sub>4</sub>C/CS/SiO<sub>2 </sub>coating has excellent antibacterial performance, and the antibacterial rate reached 99.58%. Considering all characteristics required for biological applications, the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating demonstrates promising potential for bone implant applications on 316L stainless steel.

Authors

Publication Details

Journal
Friction
Published
2024-12-06
DOI
https://doi.org/10.26599/frict.2025.9441009
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of B 4C/CS/SiO 2 coating on SS316L for bone implants: Tribological, biological, and antibacterial properties

Minhao Zhu, Xiaomeng Xie, Tao Dang, Xiaocui Wang et al.
1 citations
Friction
Orthopaedic implants and arthroplasty
0.57
article

Preparation of B 4C/CS/SiO 2 coating on SS316L for bone implants: Tribological, biological, and antibacterial properties

Minhao Zhu, Xiaomeng Xie, Tao Dang, Xiaocui Wang, Zhiyuan Zhao, Zhaobo Wu, Jun Cao
article en
1 citations

Abstract

To improve the wear and corrosion resistance, bioactivity, and antimicrobial properties of 316L stainless steel in clinical environment, three kind of composite coatings of B<sub>4</sub>C, B<sub>4</sub>C/CS, and B<sub>4</sub>C/CS/SiO<sub>2 </sub>were designed and deposited by liquid spraying, respectively. The sliding wear results showed that the B<sub>4</sub>C/CS/SiO<sub>2 </sub>coating improves the surface quality under the synergistic effects of boron carbide, chitosan, and silica, and significantly reduces friction coefficients and wear rates. The friction shear force of the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating increases due to its high hardness and elastic modulus, resulting in a high friction coefficient. However, its high hardness and dense internal structure contributes to wear reduction. Friction experiments under simulated body fluid demonstrate that friction coefficient is reduced by calcium and phosphorus. Electrochemical experiments reveal that all three composite coatings significantly reduce the corrosion rate, and the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating exhibits the best anti-corrosion performance. The vitro mineralization and cell culture experiments demonstrate that the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating has excellent cell proliferation and osteogenic properties, which are attributed to its improved hydrophilicity, increased roughness, and stimulation from Si<sup>4+</sup>. The antibacterial experiments show that the B<sub>4</sub>C/CS/SiO<sub>2 </sub>coating has excellent antibacterial performance, and the antibacterial rate reached 99.58%. Considering all characteristics required for biological applications, the B<sub>4</sub>C/CS/SiO<sub>2</sub> coating demonstrates promising potential for bone implant applications on 316L stainless steel.

FrictionVol. 13(8)
Zero hunger
Openalex Percentile: Top 27%
Orthopaedic implants and arthroplasty
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Preparation of B <sub>4</sub>C/CS/SiO <sub>2</sub> coating on SS316L for bone implants: Tribological, biological, and antibacterial properties — Minhao Zhu, Xiaomeng Xie, et al. · Friction (2024) | TGRS Research Map | TGRS