P-100 CORRELATION OF TWO TRANSIENT ELASTOGRAPHY EQUIPMENT FOR ESTIMATION OF LIVER STEATOSIS AND LIVER FIBROSIS

No Transient elastography (TE) is an alternative diagnostic tool for estimating liver steatosis and fibrosis. Two ET devices, iLivTouch®/UAP and Fibroscan®/CAP, have shown similar diagnostic accuracy; however, no studies have evaluated the correlation of liver steatosis and fibrosis measurements between both devices in the Mexican population. Aim: To evaluate the correlation of measurement values of liver steatosis and liver fibrosis using iLivTouch®/UAP and Fibroscan®/CAP. This prospective study included adult patients who attended a check-up unit. The evaluation of liver steatosis and liver fibrosis was performed using TE with two devices (iLivTouch® FT100 and Fibroscan® 502 Touch), meeting the reliability parameters. The correlation of measurements was evaluated with the Pearson correlation coefficient; meanwhile, a Student's t-test was performed to determine differences in dB/m and kPa means. A total of 69 patients were included; 57% (n=40) were men, with a mean age and body mass index of 45±10 years and 22.4±4.5 kg/m 2 , respectively. The prevalence of diabetes mellitus was 7.2% (n=5). The mean dB/m and kPa were 266±42 dB/m and 5.8±1.2 kPa with iLivTouch® and 243±56 dB/m and 4.0±0.8 kPa with Fibroscan®. The prevalence of liver steatosis was 29% (n=20) by iLivTouch® and 20% (n=14) by Fibroscan® (p=0.32), while fibrosis was 49.3% (n=34) and 2.9%. (n=2), respectively, (p=0.0001). The mean difference for dB/m was -22.6, p≤0.0001, while for kPa, the difference was 1.72, p≤0.0001. According to the correlation analysis, this was r=0.73 (strong), p≤0.0001 for the estimation of liver steatosis, and r=0.35 (moderate), p=0.003 for the estimation of liver fibrosis. TE devices iLivTouch® and Fibroscan® show a strong correlation for estimating liver steatosis and a moderate correlation for estimating liver fibrosis.

Authors

Institutions

Publication Details

Journal
Annals of Hepatology
Published
2024-12-01
DOI
https://doi.org/10.1016/j.aohep.2024.101714
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-100 CORRELATION OF TWO TRANSIENT ELASTOGRAPHY EQUIPMENT FOR ESTIMATION OF LIVER STEATOSIS AND LIVER FIBROSIS

Eva Juárez Hernández, Ryan Mendoza, Michael E. Alfaro, Ricardo Rojo et al.
Annals of Hepatology
Liver Disease Diagnosis and Treatment
article

P-100 CORRELATION OF TWO TRANSIENT ELASTOGRAPHY EQUIPMENT FOR ESTIMATION OF LIVER STEATOSIS AND LIVER FIBROSIS

Eva Juárez Hernández, Ryan Mendoza, Michael E. Alfaro, Ricardo Rojo, Irene Méndez, Graciela Castro Narro, M. Ostos
article en

Abstract

No Transient elastography (TE) is an alternative diagnostic tool for estimating liver steatosis and fibrosis. Two ET devices, iLivTouch®/UAP and Fibroscan®/CAP, have shown similar diagnostic accuracy; however, no studies have evaluated the correlation of liver steatosis and fibrosis measurements between both devices in the Mexican population. Aim: To evaluate the correlation of measurement values of liver steatosis and liver fibrosis using iLivTouch®/UAP and Fibroscan®/CAP. This prospective study included adult patients who attended a check-up unit. The evaluation of liver steatosis and liver fibrosis was performed using TE with two devices (iLivTouch® FT100 and Fibroscan® 502 Touch), meeting the reliability parameters. The correlation of measurements was evaluated with the Pearson correlation coefficient; meanwhile, a Student's t-test was performed to determine differences in dB/m and kPa means. A total of 69 patients were included; 57% (n=40) were men, with a mean age and body mass index of 45±10 years and 22.4±4.5 kg/m 2 , respectively. The prevalence of diabetes mellitus was 7.2% (n=5). The mean dB/m and kPa were 266±42 dB/m and 5.8±1.2 kPa with iLivTouch® and 243±56 dB/m and 4.0±0.8 kPa with Fibroscan®. The prevalence of liver steatosis was 29% (n=20) by iLivTouch® and 20% (n=14) by Fibroscan® (p=0.32), while fibrosis was 49.3% (n=34) and 2.9%. (n=2), respectively, (p=0.0001). The mean difference for dB/m was -22.6, p≤0.0001, while for kPa, the difference was 1.72, p≤0.0001. According to the correlation analysis, this was r=0.73 (strong), p≤0.0001 for the estimation of liver steatosis, and r=0.35 (moderate), p=0.003 for the estimation of liver fibrosis. TE devices iLivTouch® and Fibroscan® show a strong correlation for estimating liver steatosis and a moderate correlation for estimating liver fibrosis.

Annals of HepatologyVol. 29
Hospital Médica Sur (MX)
Openalex Percentile: Top 67%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.