A Time-Limited Adaptive Reclosing Method in Active Distribution Networks Considering Anti-Islanding Protection

In active distribution networks (DNs), distributed energy resources (DERs) must be disconnected from the grid prior to automatic reclosing actions. Many scholars have proposed non-voltage checking reclosing methods, but a significant challenge arises; many substations lack line-side voltage transformers (LSVTs), making these schemes impractical. To address this, we introduce a time-limited adaptive automatic reclosing (TLAR) method that integrates DERs’ anti-islanding protection (AIP) with automatic reclosing. This method estimates the AIP action time using bus-side voltage measurements before the system-side protection (SSP) is tripped and adjusts the reclosing time accordingly to enhance power supply reliability. Simulations using PSCAD validate the method’s effectiveness. The TLAR method is well-suited for distribution lines without conditions for non-voltage checking, is cost-effective, easy to implement, and contributes to power system stability.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-12-06
DOI
https://doi.org/10.3390/pr12122781
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Time-Limited Adaptive Reclosing Method in Active Distribution Networks Considering Anti-Islanding Protection

Kaijun Fan, Fan Yang, Zhichun Yang, Hechong Chen et al.
1 citations
Processes
Power Systems Fault Detection
0.33
article

A Time-Limited Adaptive Reclosing Method in Active Distribution Networks Considering Anti-Islanding Protection

Kaijun Fan, Fan Yang, Zhichun Yang, Hechong Chen, Yu Chen, Yong Cai, Bingyin Xu
article en
1 citations

Abstract

In active distribution networks (DNs), distributed energy resources (DERs) must be disconnected from the grid prior to automatic reclosing actions. Many scholars have proposed non-voltage checking reclosing methods, but a significant challenge arises; many substations lack line-side voltage transformers (LSVTs), making these schemes impractical. To address this, we introduce a time-limited adaptive automatic reclosing (TLAR) method that integrates DERs’ anti-islanding protection (AIP) with automatic reclosing. This method estimates the AIP action time using bus-side voltage measurements before the system-side protection (SSP) is tripped and adjusts the reclosing time accordingly to enhance power supply reliability. Simulations using PSCAD validate the method’s effectiveness. The TLAR method is well-suited for distribution lines without conditions for non-voltage checking, is cost-effective, easy to implement, and contributes to power system stability.

ProcessesVol. 12(12)
Shandong University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 39%
Power Systems Fault Detection
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.