Classification of leakage current odd harmonic component of aged insulator surface condition under different relative humidity using crest factor

The impact of pollution on insulator surface performance has been extensively studied to continuously improve the insulator performance using suitable condition monitoring, including using the leakage current harmonic component analysis. However, the analysis of harmonic components, particularly in relation to the odd harmonics of the leakage current in aged insulators under the influence of contamination and humidity, is still not fully understood and remains deficient. In this paper, the leakage current of aged and polluted insulators under different environmental conditions are investigated. The study was conducted experimentally using twelve samples of insulators with varying degrees of aging. The crest factor was employed as an indicator of the leakage current index. The findings showed that the odd harmonic crest factor demonstrates high sensitivity in classifying the degree of aging in contaminated insulators.

Authors

Institutions

Publication Details

Journal
Archives of Electrical Engineering
Published
2024-12-04
DOI
https://doi.org/10.24425/aee.2024.152111
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Classification of leakage current odd harmonic component of aged insulator surface condition under different relative humidity using crest factor

Zulkurnain Abdul‐Malek, Umar Ali Benisheikh, Anwar Ali Sahito
1 citations
Archives of Electrical Engineering
High voltage insulation and dielectric phenomena
0.12
article

Classification of leakage current odd harmonic component of aged insulator surface condition under different relative humidity using crest factor

Zulkurnain Abdul‐Malek, Umar Ali Benisheikh, Anwar Ali Sahito
article en
1 citations

Abstract

The impact of pollution on insulator surface performance has been extensively studied to continuously improve the insulator performance using suitable condition monitoring, including using the leakage current harmonic component analysis. However, the analysis of harmonic components, particularly in relation to the odd harmonics of the leakage current in aged insulators under the influence of contamination and humidity, is still not fully understood and remains deficient. In this paper, the leakage current of aged and polluted insulators under different environmental conditions are investigated. The study was conducted experimentally using twelve samples of insulators with varying degrees of aging. The crest factor was employed as an indicator of the leakage current index. The findings showed that the odd harmonic crest factor demonstrates high sensitivity in classifying the degree of aging in contaminated insulators.

Archives of Electrical Engineering
University of Technology Malaysia (MY), University of Maiduguri (NG)
Openalex Percentile: Top 57%
High voltage insulation and dielectric phenomena
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Classification of leakage current odd harmonic component of aged insulator surface condition under different relative humidity using crest factor — Zulkurnain Abdul‐Malek, Umar Ali Benisheikh, et al. · Archives of Electrical Engineering (2024) | TGRS Research Map | TGRS