Magnetic nanoparticle-mediated non-invasive imaging and eradication of lymph nodes

Regional lymph node (LN) dissection is often used for the treatment of deep LNs in tumour surgery; however, the method is prone to incomplete LN dissection, trauma, complications, and other side effects. LN tracers make it easier to visualise and remove LNs. However, the current common LN tracers only have a single function or have radiation hazards related to their use. Therefore, the use of multi-functional LN tracers to improve the efficiency of deep LN eradication and reduce trauma and complications is currently a major challenge to be addressed. This study aimed to develop a multi-functional citrate-coated magnetite nanoparticle (CMNP) that could specifically drain to and accumulate in LNs. The CMNPs can be used as photoacoustic imaging contrast agents and magnetic resonance imaging contrast agents to image LNs. When an alternating magnetic field is applied, the CMNP can generate heat and raise the temperature of LNs, which is sufficient to coagulate and necrotise the LNs, thereby achieving LN inactivation. Eradication of LNs by magnetic hyperthermia is not limited by depth, and only LNs are specifically heated. Moreover, the method is less invasive and accurate for deep LNs.

Authors

Institutions

Publication Details

Journal
Nanoscale
Published
2024-12-06
DOI
https://doi.org/10.1039/d4nr04772a
Citations
1
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic nanoparticle-mediated non-invasive imaging and eradication of lymph nodes

Xiaojun Cai, Dechao Niu, Wei Gao, Yan Wang et al.
1 citations
Nanoscale
Radiomics and Machine Learning in Medical Imaging
0.40
article

Magnetic nanoparticle-mediated non-invasive imaging and eradication of lymph nodes

Xiaojun Cai, Dechao Niu, Wei Gao, Yan Wang, Yuanyi Zheng
article en
1 citations

Abstract

Regional lymph node (LN) dissection is often used for the treatment of deep LNs in tumour surgery; however, the method is prone to incomplete LN dissection, trauma, complications, and other side effects. LN tracers make it easier to visualise and remove LNs. However, the current common LN tracers only have a single function or have radiation hazards related to their use. Therefore, the use of multi-functional LN tracers to improve the efficiency of deep LN eradication and reduce trauma and complications is currently a major challenge to be addressed. This study aimed to develop a multi-functional citrate-coated magnetite nanoparticle (CMNP) that could specifically drain to and accumulate in LNs. The CMNPs can be used as photoacoustic imaging contrast agents and magnetic resonance imaging contrast agents to image LNs. When an alternating magnetic field is applied, the CMNP can generate heat and raise the temperature of LNs, which is sufficient to coagulate and necrotise the LNs, thereby achieving LN inactivation. Eradication of LNs by magnetic hyperthermia is not limited by depth, and only LNs are specifically heated. Moreover, the method is less invasive and accurate for deep LNs.

NanoscaleVol. 17(12)
East China University of Science and Technology (CN), Shanghai Sixth People's Hospital (CN)
Openalex Percentile: Top 32%
Radiomics and Machine Learning in Medical Imaging
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.