Effects of skin tone and adipose thickness on frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

SignificanceFrequency domain near-infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) are used for the label-free measurement of chromophore concentrations, blood flow, and metabolism for tissues such as muscle or tumors. These tissues are embedded under the skin and adipose, the properties of which can vary between subjects, thus affecting the extraction of the target tissue’s optical properties.AimWe aim to characterize the effects of the skin tone and adipose thickness on FD-NIRS and DCS measurements and develop subject-specific multi-layer inverse models that account for these effects.ApproachA three-layer look-up-table-based inverse model that accounted for the skin tone and adipose thickness was generated using Monte Carlo simulations for each subject. Stackable tissue-mimicking silicone phantoms were fabricated and used to validate the models. A custom combined FD-NIRS and DCS system was then used to measure phantoms and the sternocleidomastoid muscle of healthy subjects. Subjects performed a breathing exercise that consisted of a baseline, load, and recovery. The skin tone of subjects was determined using a colorimeter. The adipose thickness was determined using ultrasound. The subject-specific three-layer model results were compared against a simpler single-layer model.ResultsThe skin tone and adipose thickness substantially affected the extraction of multiple FD-NIRS and DCS parameters. Oxygenated hemoglobin, total hemoglobin, tissue saturation (StO2), and blood flow index (BFi) values were all underestimated if the skin tone and adipose thickness were not accounted for (all p-values<0.01). For example, StO2 was underestimated by 18±9 %pt (p<0.0001) and BFi was underestimated by 7±8×10−6 mm2/s (p<0.01). Hemodynamics during a respiratory exercise were also underestimated in the case of oxygenated hemoglobin, total hemoglobin, BFi, and metabolic rate of oxygenation (all p<0.05).ConclusionWe highlight the importance of accounting for both adipose thickness and skin tone when targeting underlying tissue. The multi-layer models we developed have the potential to be applied to a wide range of in vivo studies.

Authors

Institutions

Publication Details

Journal
Biophotonics discovery.
Published
2024-12-06
DOI
https://doi.org/10.1117/1.bios.2.1.012503
Citations
6
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
3.97
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of skin tone and adipose thickness on frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

Darren Roblyer, Carlos A. Gómez
6 citations
Biophotonics discovery.
Spectroscopy Techniques in Biomedical and Chemical Research
3.97
article

Effects of skin tone and adipose thickness on frequency domain near-infrared spectroscopy and diffuse correlation spectroscopy

Darren Roblyer, Carlos A. Gómez
article en
6 citations

Abstract

SignificanceFrequency domain near-infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) are used for the label-free measurement of chromophore concentrations, blood flow, and metabolism for tissues such as muscle or tumors. These tissues are embedded under the skin and adipose, the properties of which can vary between subjects, thus affecting the extraction of the target tissue’s optical properties.AimWe aim to characterize the effects of the skin tone and adipose thickness on FD-NIRS and DCS measurements and develop subject-specific multi-layer inverse models that account for these effects.ApproachA three-layer look-up-table-based inverse model that accounted for the skin tone and adipose thickness was generated using Monte Carlo simulations for each subject. Stackable tissue-mimicking silicone phantoms were fabricated and used to validate the models. A custom combined FD-NIRS and DCS system was then used to measure phantoms and the sternocleidomastoid muscle of healthy subjects. Subjects performed a breathing exercise that consisted of a baseline, load, and recovery. The skin tone of subjects was determined using a colorimeter. The adipose thickness was determined using ultrasound. The subject-specific three-layer model results were compared against a simpler single-layer model.ResultsThe skin tone and adipose thickness substantially affected the extraction of multiple FD-NIRS and DCS parameters. Oxygenated hemoglobin, total hemoglobin, tissue saturation (StO2), and blood flow index (BFi) values were all underestimated if the skin tone and adipose thickness were not accounted for (all p-values<0.01). For example, StO2 was underestimated by 18±9 %pt (p<0.0001) and BFi was underestimated by 7±8×10−6 mm2/s (p<0.01). Hemodynamics during a respiratory exercise were also underestimated in the case of oxygenated hemoglobin, total hemoglobin, BFi, and metabolic rate of oxygenation (all p<0.05).ConclusionWe highlight the importance of accounting for both adipose thickness and skin tone when targeting underlying tissue. The multi-layer models we developed have the potential to be applied to a wide range of in vivo studies.

Biophotonics discovery.Vol. 2(01)
Boston University (US)
Openalex Percentile: Top 7%
Spectroscopy Techniques in Biomedical and Chemical Research
3.97
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.