Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony

ECG imaging can bring a significant value into assessing the efficacy of new pacing modalities and provide much more data for precise determination of implantation outcome including detailed activation assessment and comparison with intrinsic conduction. Key ECGI values confirming proper ventricular activation have been defined, and corresponding 12-lead parameters were also identified, which allows to predict ventricular activation by using 12-lead ECG only.

Authors

Institutions

Publication Details

Journal
Heart Rhythm O2
Published
2024-12-06
DOI
https://doi.org/10.1016/j.hroo.2024.11.026
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony

Ali Gharaviri, Carlo de Asmundis, Ingrid Overeinder, Erwin Ströker et al.
1 citations
Heart Rhythm O2
Cardiac pacing and defibrillation studies
0.40
article

Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony

Ali Gharaviri, Carlo de Asmundis, Ingrid Overeinder, Erwin Ströker, Ivan Eltsov, Luigi Pannone, Frederik H. Verbrugge, Roberto Scacciavillani, Gezim Bala, Gian‐Battista Chierchia, Alvise Del Monte, Andrea Sarkozy, Domenico Giovanni Della Rocca, Giacomo Talevi, Alexandre Almorad, Juan Sieira, Qingguo Zeng, Mark La Meir, A Paparella
article en
1 citations

Abstract

ECG imaging can bring a significant value into assessing the efficacy of new pacing modalities and provide much more data for precise determination of implantation outcome including detailed activation assessment and comparison with intrinsic conduction. Key ECGI values confirming proper ventricular activation have been defined, and corresponding 12-lead parameters were also identified, which allows to predict ventricular activation by using 12-lead ECG only.

Heart Rhythm O2Vol. 6(3)
Vrije Universiteit Brussel (BE), Medtronic (United States) (US), Universitair Ziekenhuis Brussel (BE), ERN GUARD-Heart (NL)
Zero hunger
Openalex Percentile: Top 30%
Cardiac pacing and defibrillation studies
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Noninvasive electrocardiographic imaging assessment of conduction system pacing: A novel algorithm to assess intraventricular synchrony — Ali Gharaviri, Carlo de Asmundis, et al. · Heart Rhythm O2 (2024) | TGRS Research Map | TGRS