Electrochemical behaviour of amodiaquine detection using boron doped diamond electrodes

In this study, we propose a simple and low-cost procedure by using boron-doped diamond (BDD) as a working electrode to detect amodiaquine (AQ) in phosphate buffer solution (PBS) and potassium perchlorate (KClO 4 ) electrolytes. We used cyclic voltammetry (CV) and different pulse voltammetry (DPV) techniques. By using DPV, oxidation of AQ in PBS and KClO4 was observed at +0.28 V and +0.4 V ( vs. Ag/AgCl), respectively. To investigate the redox reaction mechanism, the pH and scan rate were varied. A linear calibration curve was observed in the concentration range of 0.0645 – 0.3 µM with a detection limit of 1.47×10 -3 µM (S/N=3) for PBS and 4.81×10 -3 µM (S/N=3) for KClO 4 . This result confirms that BDD electrodes could potentially be used to detect AQ.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-12-06
DOI
https://doi.org/10.1016/j.ijoes.2024.100913
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical behaviour of amodiaquine detection using boron doped diamond electrodes

Yunita Triana, Fredy Kurniawan, Yasuaki Einaga, Genki Ogata et al.
4 citations
International Journal of Electrochemical Science
Electrochemical sensors and biosensors
0.83
article

Electrochemical behaviour of amodiaquine detection using boron doped diamond electrodes

Yunita Triana, Fredy Kurniawan, Yasuaki Einaga, Genki Ogata, Muhammad Raihan Ramadhan, Murni Handayani, Meutya Dwi Leoriza, Nessa Sabriena, Andi Idhil Ismail, Keysi Devain Destiny
article en
4 citations

Abstract

In this study, we propose a simple and low-cost procedure by using boron-doped diamond (BDD) as a working electrode to detect amodiaquine (AQ) in phosphate buffer solution (PBS) and potassium perchlorate (KClO 4 ) electrolytes. We used cyclic voltammetry (CV) and different pulse voltammetry (DPV) techniques. By using DPV, oxidation of AQ in PBS and KClO4 was observed at +0.28 V and +0.4 V ( vs. Ag/AgCl), respectively. To investigate the redox reaction mechanism, the pH and scan rate were varied. A linear calibration curve was observed in the concentration range of 0.0645 – 0.3 µM with a detection limit of 1.47×10 -3 µM (S/N=3) for PBS and 4.81×10 -3 µM (S/N=3) for KClO 4 . This result confirms that BDD electrodes could potentially be used to detect AQ.

International Journal of Electrochemical ScienceVol. 20(1)
Sepuluh Nopember Institute of Technology (ID), Keio University (JP), Institut Teknologi Kalimantan (ID), National Nuclear Energy Agency of Indonesia (ID)
Clean water and sanitation
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.