An interference in bilirubin detection: Pulmonary marginal zone lymphoma presenting monoclonal cryoglobulin

Marginal zone lymphoma (MZL) of the lung is an indolent B-cell lymphoma. The peripheral blood of most patients with pulmonary MZL contains low or undetectable monoclonal immunoglobulin (M protein) levels. In this case, the clinical laboratory discovered that the pulmonary MZL patient not only associated with high concentration of monoclonal IgG-type protein but also exhibited obvious gel formation characteristics that interfered with clinical biochemistry tests. Thus, the role of M protein in total bilirubin determination was examined in this study. Total bilirubin detection curve difference comparison between monoclonal IgG protein and polyclonal immunoglobulin, interference experiments, and dilution elimination experiments were conducted. These experiments revealed not only a positive correlation between M protein interference in bilirubin detection with its concentration, but also M protein-specific interference distinct from polyclonal immunoglobulin. We employed the R and EmpowerStat statistical systems to evaluate the correlation between serum monoclonal protein and total bilirubin absorbance curve data. Multivariate analysis revealed a nonlinear correlation between with globulin (GLB) and square root transformed curve optical density (OD) data. The receiver operating characteristic (ROC) curve analysis indicated an area under the curve (AUC) of 0.852 for the GLB ≥ 31.9 g/L subgroup using combined curve indicators. Our findings can enhance clinical M protein screening and scientific assessment of the populations requiring serum protein electrophoresis testing, thereby reducing the rate of missed diagnoses in the M protein population.

Authors

Institutions

Publication Details

Journal
Clinica Chimica Acta
Published
2024-12-06
DOI
https://doi.org/10.1016/j.cca.2024.120066
Citations
1
Primary Topic
Neuroendocrine Tumor Research Advances
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An interference in bilirubin detection: Pulmonary marginal zone lymphoma presenting monoclonal cryoglobulin

Kaiyong Cai, L Zhang, Xiao-Ge Luo, Li Yi et al.
1 citations
Clinica Chimica Acta
Neuroendocrine Tumor Research Advances
0.39
article

An interference in bilirubin detection: Pulmonary marginal zone lymphoma presenting monoclonal cryoglobulin

Kaiyong Cai, L Zhang, Xiao-Ge Luo, Li Yi, Lei Zhou, Kangyi Wang
article en
1 citations

Abstract

Marginal zone lymphoma (MZL) of the lung is an indolent B-cell lymphoma. The peripheral blood of most patients with pulmonary MZL contains low or undetectable monoclonal immunoglobulin (M protein) levels. In this case, the clinical laboratory discovered that the pulmonary MZL patient not only associated with high concentration of monoclonal IgG-type protein but also exhibited obvious gel formation characteristics that interfered with clinical biochemistry tests. Thus, the role of M protein in total bilirubin determination was examined in this study. Total bilirubin detection curve difference comparison between monoclonal IgG protein and polyclonal immunoglobulin, interference experiments, and dilution elimination experiments were conducted. These experiments revealed not only a positive correlation between M protein interference in bilirubin detection with its concentration, but also M protein-specific interference distinct from polyclonal immunoglobulin. We employed the R and EmpowerStat statistical systems to evaluate the correlation between serum monoclonal protein and total bilirubin absorbance curve data. Multivariate analysis revealed a nonlinear correlation between with globulin (GLB) and square root transformed curve optical density (OD) data. The receiver operating characteristic (ROC) curve analysis indicated an area under the curve (AUC) of 0.852 for the GLB ≥ 31.9 g/L subgroup using combined curve indicators. Our findings can enhance clinical M protein screening and scientific assessment of the populations requiring serum protein electrophoresis testing, thereby reducing the rate of missed diagnoses in the M protein population.

Clinica Chimica ActaVol. 567
Army Medical University (CN), Dalian Medical University (CN), Second Affiliated Hospital of Chongqing Medical University (CN), Ministry of Education (TH), Chongqing Medical University (CN)
Zero hunger
Openalex Percentile: Top 31%
Neuroendocrine Tumor Research Advances
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.