Super-resolution ultrasound imaging of ischaemia flow: An in silico study

Super-resolution ultrasound (SRU) is a new ultrasound imaging mode that promises to facilitate the detection of microvascular disease by providing new vascular bio-markers that are directly linked to microvascular pathophysiology, thereby augmenting current knowledge and potentially enabling new treatment. Such a capability can be developed through thorough understanding as articulated by means of mathematical models. In this study, a 2D numerical flow model is adopted for generating flow adaptation in response to ischaemia, in order to determine the ability of SRU to register the resulting flow perturbations. The flow model results demonstrate that variations in flow behaviour in response to locally induced ischaemia can be significant throughout the entire vascular bed. Measured velocities have variations that are dependent on the location of ischaemia, with median values ranging between 2-7 mms<sup>-1</sup>. Moreover, the distinction between healthy and ischaemic networks are recorded accurately in the SRU results showing excellent agreement between SRU maps and the model. Up to 7-fold spatial resolution improvement to conventional contrast ultrasound was achieved in microbubble localisation while the detection precision and recall was consistently above 98%. The microbubble tracking precision was of a similar accuracy, whereas the recall was reduced (77%) under varying ischaemic impacted flow. Further, regions with velocities up to 30 mms<sup>-1</sup> are in excellent agreement with SRU maps, while at regions that include a proportion of higher velocities, the median velocity values are within 1.28%-3.32% of the ground-truth. In conclusion, SRU is a highly promising methodology for the direct measurement of microvascular flow dynamics and may provide a valuable tool for the understanding and subsequent modelling of behaviour in the vascular bed.

Authors

Institutions

Publication Details

Journal
Journal of Theoretical Biology
Published
2024-12-06
DOI
https://doi.org/10.1016/j.jtbi.2024.112018
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-resolution ultrasound imaging of ischaemia flow: An in silico study

Γεώργιος Παπαγεωργίου, Weiping Lu, Lachlan Arthur, Vasiliki Voulgaridou et al.
1 citations
Journal of Theoretical Biology
Photoacoustic and Ultrasonic Imaging
0.18
article

Super-resolution ultrasound imaging of ischaemia flow: An in silico study

Γεώργιος Παπαγεωργίου, Weiping Lu, Lachlan Arthur, Vasiliki Voulgaridou, Vassilis Sboros, Steven Robert McDougall
article en
1 citations

Abstract

Super-resolution ultrasound (SRU) is a new ultrasound imaging mode that promises to facilitate the detection of microvascular disease by providing new vascular bio-markers that are directly linked to microvascular pathophysiology, thereby augmenting current knowledge and potentially enabling new treatment. Such a capability can be developed through thorough understanding as articulated by means of mathematical models. In this study, a 2D numerical flow model is adopted for generating flow adaptation in response to ischaemia, in order to determine the ability of SRU to register the resulting flow perturbations. The flow model results demonstrate that variations in flow behaviour in response to locally induced ischaemia can be significant throughout the entire vascular bed. Measured velocities have variations that are dependent on the location of ischaemia, with median values ranging between 2-7 mms<sup>-1</sup>. Moreover, the distinction between healthy and ischaemic networks are recorded accurately in the SRU results showing excellent agreement between SRU maps and the model. Up to 7-fold spatial resolution improvement to conventional contrast ultrasound was achieved in microbubble localisation while the detection precision and recall was consistently above 98%. The microbubble tracking precision was of a similar accuracy, whereas the recall was reduced (77%) under varying ischaemic impacted flow. Further, regions with velocities up to 30 mms<sup>-1</sup> are in excellent agreement with SRU maps, while at regions that include a proportion of higher velocities, the median velocity values are within 1.28%-3.32% of the ground-truth. In conclusion, SRU is a highly promising methodology for the direct measurement of microvascular flow dynamics and may provide a valuable tool for the understanding and subsequent modelling of behaviour in the vascular bed.

Journal of Theoretical BiologyVol. 599
Heriot-Watt University (GB), Centre for Inflammation Research (GB)
British Heart Foundation, Science and Technology Facilities Council
Openalex Percentile: Top 50%
Photoacoustic and Ultrasonic Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.