Awake rodent fMRI: Gradient-echo echo planar imaging versus compressed-sensing fast low-angle shot

Awake rodent functional magnetic resonance imaging (fMRI) is increasingly becoming a reliable neuroimaging technique to study neuronal activity at both the whole-brain and high-resolution laminar scales. Prior studies have focused on developing acclimation protocols, experimental paradigms, and hardware to optimize outcomes. However, little effort has been made to address the impact of pulse sequence selection on detecting brain activation in awake fMRI experiments. In the current study, we compare gradient-echo echo planar imaging (GE-EPI) and compressed-sensing fast low-angle shot (CS-FLASH) sequences with cerebral blood volume-weighted (CBVw) contrast enhancement to investigate their sensitivity to hemodynamic activity in the olfactory bulb of awake rodents. Compared with GE-EPI, CS-FLASH had comparable motion parameters but was more sensitive to large motions, often resulting in corruption of the image quality. The use of framewise displacement as a motion censoring technique may over censor the data, requiring alternative approaches, such as spatial correlation censoring. CS-FLASH images were qualitatively sharper than GE-EPI; however, the contrast-to-noise ratio for odor activation was consistently greater for GE-EPI than for CS-FLASH that cannot be explained by olfactory adaptation alone. The activation maps of CS-FLASH to four different odors showed spatially unique patterns consistent with GE-EPI, but with lower z-scores or detection sensitivity. Activation maps were consistent with previously established histological findings. Additionally, odor-evoked laminar activation was greatest in the superficial layers that decreased with laminar depth, consistent with prior findings. We conclude that CS-FLASH produces sharper images with equivalent spatial activation maps to GE-EPI, albeit with lower statistical strength and contrast-to-noise ratio (CNR), and without being prohibited by motion-related image distortion.

Authors

Institutions

Publication Details

Journal
Imaging Neuroscience
Published
2024-12-06
DOI
https://doi.org/10.1162/imag_a_00406
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Awake rodent fMRI: Gradient-echo echo planar imaging versus compressed-sensing fast low-angle shot

Christopher G. Cover, Alexander John Poplawsky, Mitsuhiro Fukuda, Alberto L. Vazquez et al.
1 citations
Imaging Neuroscience
Advanced MRI Techniques and Applications
0.40
article

Awake rodent fMRI: Gradient-echo echo planar imaging versus compressed-sensing fast low-angle shot

Christopher G. Cover, Alexander John Poplawsky, Mitsuhiro Fukuda, Alberto L. Vazquez, Sujatha S. Reddy
article en
1 citations

Abstract

Awake rodent functional magnetic resonance imaging (fMRI) is increasingly becoming a reliable neuroimaging technique to study neuronal activity at both the whole-brain and high-resolution laminar scales. Prior studies have focused on developing acclimation protocols, experimental paradigms, and hardware to optimize outcomes. However, little effort has been made to address the impact of pulse sequence selection on detecting brain activation in awake fMRI experiments. In the current study, we compare gradient-echo echo planar imaging (GE-EPI) and compressed-sensing fast low-angle shot (CS-FLASH) sequences with cerebral blood volume-weighted (CBVw) contrast enhancement to investigate their sensitivity to hemodynamic activity in the olfactory bulb of awake rodents. Compared with GE-EPI, CS-FLASH had comparable motion parameters but was more sensitive to large motions, often resulting in corruption of the image quality. The use of framewise displacement as a motion censoring technique may over censor the data, requiring alternative approaches, such as spatial correlation censoring. CS-FLASH images were qualitatively sharper than GE-EPI; however, the contrast-to-noise ratio for odor activation was consistently greater for GE-EPI than for CS-FLASH that cannot be explained by olfactory adaptation alone. The activation maps of CS-FLASH to four different odors showed spatially unique patterns consistent with GE-EPI, but with lower z-scores or detection sensitivity. Activation maps were consistent with previously established histological findings. Additionally, odor-evoked laminar activation was greatest in the superficial layers that decreased with laminar depth, consistent with prior findings. We conclude that CS-FLASH produces sharper images with equivalent spatial activation maps to GE-EPI, albeit with lower statistical strength and contrast-to-noise ratio (CNR), and without being prohibited by motion-related image distortion.

Imaging NeuroscienceVol. 3
University of Pittsburgh (US), McGowan Institute for Regenerative Medicine (US)
University of Pittsburgh, National Institutes of Health
Openalex Percentile: Top 32%
Advanced MRI Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.