A Modified Power System Frequency Response Model Incorporating DFIG Primary Frequency Control Dynamics

Wind turbines (WTs) provision of frequency support has become a must due to the reduction of system inertia caused by their replacement of conventional synchronous generators (SGs). The addition of frequency control complicates WT's frequency response, which hinders power system’ planning and operation for the assurance of frequency stability. To address this issue, the paper takes doubly-fed induction generator (DFIG) based WT as an example, and proposes a modified power system frequency response (SFR) model. Firstly, allowing for the mechanical and control behavior of DFIG electromechanical dynamics, a synthetic motion equation model is built to explicitly characterize its inertia and damping characteristics. Then, considering system power balance relation, a modified SFR model is constructed by inserting the DFIG submodule. And lastly, time-domain simulation is conducted in Matlab/Simulink to verify the accuracy of the proposed model.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768665
Citations
2
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modified Power System Frequency Response Model Incorporating DFIG Primary Frequency Control Dynamics

Dong Wang, Yuanjing Lu, Yunhui Huang, Xiaomei Qu et al.
2 citations
Power Systems and Renewable Energy
0.34
article

A Modified Power System Frequency Response Model Incorporating DFIG Primary Frequency Control Dynamics

Dong Wang, Yuanjing Lu, Yunhui Huang, Xiaomei Qu, Keliang Zhou, Yajun Guo, Junzhang Tian, Jun Jun
article en
2 citations

Abstract

Wind turbines (WTs) provision of frequency support has become a must due to the reduction of system inertia caused by their replacement of conventional synchronous generators (SGs). The addition of frequency control complicates WT's frequency response, which hinders power system’ planning and operation for the assurance of frequency stability. To address this issue, the paper takes doubly-fed induction generator (DFIG) based WT as an example, and proposes a modified power system frequency response (SFR) model. Firstly, allowing for the mechanical and control behavior of DFIG electromechanical dynamics, a synthetic motion equation model is built to explicitly characterize its inertia and damping characteristics. Then, considering system power balance relation, a modified SFR model is constructed by inserting the DFIG submodule. And lastly, time-domain simulation is conducted in Matlab/Simulink to verify the accuracy of the proposed model.

Wuhan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 33%
Power Systems and Renewable Energy
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.