Comparison of Anterior Chamber Depth before and after Cataract Surgery by Phacoemulsification with IOL Implantation

Objective: The purpose of this study was to compare the changes in anterior chamber depth before and after cataract surgery by phacoemulsification with posterior chamber intraocular lens implantation. Methodology: This was comparative pre and post-operative observational study in which 75 patients included who underwent for cataract surgery via phacoemulsification with posterior chamber IOL implantation. ACD is measured on A-scan before surgery and after surgery at 1 week and 1 month. Results: Out of 75 patients who participated in this study, there were 31 (41.3%) males and 44 (58.7%) females. The mean anterior chamber depth increased from 2.9548 ± 0.41785 mm to 3.1928 ± 0.31698 mm with a mean increase of -0.23800 ± 0.44520 mm. There was statistically significant difference in the mean change anterior chamber depth. Conclusion: The anterior chamber was deepened by phacoemulsification and IOL implantation. Key words: Cataract, Anterior chamber depth, Phacoemulsification

Authors

Institutions

Publication Details

Journal
Ophthalmology Pakistan
Published
2024-12-04
DOI
https://doi.org/10.62276/ophthalmolpak.14.04.159
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Anterior Chamber Depth before and after Cataract Surgery by Phacoemulsification with IOL Implantation

Nabila Zulfiqar, Muhammad Hamza Najam, Sara Iqbal, Aleena Nadeem et al.
Ophthalmology Pakistan
Intraocular Surgery and Lenses
article

Comparison of Anterior Chamber Depth before and after Cataract Surgery by Phacoemulsification with IOL Implantation

Nabila Zulfiqar, Muhammad Hamza Najam, Sara Iqbal, Aleena Nadeem, Nimra Ayoub
article en

Abstract

Objective: The purpose of this study was to compare the changes in anterior chamber depth before and after cataract surgery by phacoemulsification with posterior chamber intraocular lens implantation. Methodology: This was comparative pre and post-operative observational study in which 75 patients included who underwent for cataract surgery via phacoemulsification with posterior chamber IOL implantation. ACD is measured on A-scan before surgery and after surgery at 1 week and 1 month. Results: Out of 75 patients who participated in this study, there were 31 (41.3%) males and 44 (58.7%) females. The mean anterior chamber depth increased from 2.9548 ± 0.41785 mm to 3.1928 ± 0.31698 mm with a mean increase of -0.23800 ± 0.44520 mm. There was statistically significant difference in the mean change anterior chamber depth. Conclusion: The anterior chamber was deepened by phacoemulsification and IOL implantation. Key words: Cataract, Anterior chamber depth, Phacoemulsification

Ophthalmology PakistanVol. 14(4)
Our Lady of Fatima Hospital (US)
Openalex Percentile: Top 64%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.