The variation in axial length in office hours causes a diopter change in the intraocular lens power calculation

PurposeTo investigate whether diurnal changes in biometric parameters at different times of the day are visible and to analyze whether the variations could have clinical significance in the process of intraocular lens (IOL) power calculation.MethodsPhakic eyes measured by IOLMaster 700 above the age of 16 were included, with the exclusion of previous surgery. Measurements were taken between 7:00 and 15:00 and data were treated in hourly groups within this range. Data such as age, sex and biometric parameters (axial length (AL), anterior chamber depth, central corneal thickness, white-to-white distance, keratometry readings, lens thickness) were used besides the hour:minute time of the examination.ResultsBiometric data from 32,596 eyes were used (38.89% males). There were no statistically significant differences in age and biometric parameters between the office-hour groups (p > 0.05), excluding the AL. The AL at the end of the day was 0.198 mm longer for male and 0.197 mm longer for female compared to the beginning of the office day. Accordingly, the results of IOL power calculation varied between 21.0 and 20.0 D for male, and 21.5 D and 20.5 D for the female population.ConclusionThe results suggest that the assessment of AL may be affected by the intraday time of the biometry. This variation is clinically significant and may have implications for the evaluation of AL.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2024-12-04
DOI
https://doi.org/10.1177/11206721241304154
Citations
1
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The variation in axial length in office hours causes a diopter change in the intraocular lens power calculation

Gábor Németh, Péter Vámosi, László Módis, Ágnes Elekes et al.
1 citations
European Journal of Ophthalmology
Corneal surgery and disorders
0.40
article

The variation in axial length in office hours causes a diopter change in the intraocular lens power calculation

Gábor Németh, Péter Vámosi, László Módis, Ágnes Elekes, Zoltán Sohajda, Ágnes Revák
article en
1 citations

Abstract

PurposeTo investigate whether diurnal changes in biometric parameters at different times of the day are visible and to analyze whether the variations could have clinical significance in the process of intraocular lens (IOL) power calculation.MethodsPhakic eyes measured by IOLMaster 700 above the age of 16 were included, with the exclusion of previous surgery. Measurements were taken between 7:00 and 15:00 and data were treated in hourly groups within this range. Data such as age, sex and biometric parameters (axial length (AL), anterior chamber depth, central corneal thickness, white-to-white distance, keratometry readings, lens thickness) were used besides the hour:minute time of the examination.ResultsBiometric data from 32,596 eyes were used (38.89% males). There were no statistically significant differences in age and biometric parameters between the office-hour groups (p > 0.05), excluding the AL. The AL at the end of the day was 0.198 mm longer for male and 0.197 mm longer for female compared to the beginning of the office day. Accordingly, the results of IOL power calculation varied between 21.0 and 20.0 D for male, and 21.5 D and 20.5 D for the female population.ConclusionThe results suggest that the assessment of AL may be affected by the intraday time of the biometry. This variation is clinically significant and may have implications for the evaluation of AL.

European Journal of OphthalmologyVol. 35(4)
University of Debrecen (HU), University of Miskolc (HU), Péterfy Sándor Utcai Kórház-Rendelőintézet és Baleseti Központ (HU)
Openalex Percentile: Top 32%
Corneal surgery and disorders
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The variation in axial length in office hours causes a diopter change in the intraocular lens power calculation — Gábor Németh, Péter Vámosi, et al. · European Journal of Ophthalmology (2024) | TGRS Research Map | TGRS