Low‐head pumped hydro storage: An evaluation of energy balancing and frequency support

Abstract Large‐scale energy storage solutions are crucial to ensure grid stability and reliability in the ongoing energy transition towards a low‐carbon, renewable energy based electricity supply. This article presents the evaluation of a novel low‐head pumped hydro storage system designed for coastal environments and shallow seas. The proposed system addresses some of the challenges of low‐head pumped hydro storage including the need for larger flow rates and reservoirs as well as the requirement of machinery with high efficiencies across a wide operating range to accommodate larger changes in gross head during storage cycles. It includes several units of contra‐rotating reversible pump‐turbines connected to axial‐flux motor generators within a ring dike, as well as dedicated machine‐ and grid‐side control. The technology allows for independent control of each runner, making it possible to adapt to the specific operating conditions of low‐head systems. In this work, a numerical approach is used to simulate the system's performance and dynamic behaviour under various operational conditions, including energy generation, storage, and grid support of a 1 GW system with 4 GWh of storage capacity. The potential system performance for energy balancing cycles is evaluated, and a sensitivity analysis is conducted to assess the influence of scaling the motor‐generators on performance and footprint of the plant. Additionally, the capability and limitations of the system to respond to grid demand fluctuations and provide frequency regulation services are assessed. The results demonstrate that the low‐head pumped hydro storage system is a viable large‐scale energy storage solution, capable of round‐trip efficiencies above 70% across a wide operating range. By increasing the maximum power of the electric machines, the maximum head range of the whole system is increased which correlates with a threefold increase in energy density per unit area. The dynamic simulations further show that the system can rapidly change its power output allowing it to provide frequency regulation services. Allocating 20% of its nominal power as a reserve, the new power setpoints can be reached within a maximum of 5 s independent of its initial state of charge.

Authors

Institutions

Publication Details

Journal
IET Renewable Power Generation
Published
2024-12-01
DOI
https://doi.org/10.1049/rpg2.13125
Citations
5
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
1.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low‐head pumped hydro storage: An evaluation of energy balancing and frequency support

Jeroen D. M. De Kooning, Håkan Nilsson, Antonio Jarquin Laguna, Daan P. K. Truijen et al.
5 citations
IET Renewable Power Generation
Microgrid Control and Optimization
1.64
article

Low‐head pumped hydro storage: An evaluation of energy balancing and frequency support

Jeroen D. M. De Kooning, Håkan Nilsson, Antonio Jarquin Laguna, Daan P. K. Truijen, Kurt Stockman, Justus Hoffstaedt, Jonathan Fahlbeck
article en
5 citations

Abstract

Abstract Large‐scale energy storage solutions are crucial to ensure grid stability and reliability in the ongoing energy transition towards a low‐carbon, renewable energy based electricity supply. This article presents the evaluation of a novel low‐head pumped hydro storage system designed for coastal environments and shallow seas. The proposed system addresses some of the challenges of low‐head pumped hydro storage including the need for larger flow rates and reservoirs as well as the requirement of machinery with high efficiencies across a wide operating range to accommodate larger changes in gross head during storage cycles. It includes several units of contra‐rotating reversible pump‐turbines connected to axial‐flux motor generators within a ring dike, as well as dedicated machine‐ and grid‐side control. The technology allows for independent control of each runner, making it possible to adapt to the specific operating conditions of low‐head systems. In this work, a numerical approach is used to simulate the system's performance and dynamic behaviour under various operational conditions, including energy generation, storage, and grid support of a 1 GW system with 4 GWh of storage capacity. The potential system performance for energy balancing cycles is evaluated, and a sensitivity analysis is conducted to assess the influence of scaling the motor‐generators on performance and footprint of the plant. Additionally, the capability and limitations of the system to respond to grid demand fluctuations and provide frequency regulation services are assessed. The results demonstrate that the low‐head pumped hydro storage system is a viable large‐scale energy storage solution, capable of round‐trip efficiencies above 70% across a wide operating range. By increasing the maximum power of the electric machines, the maximum head range of the whole system is increased which correlates with a threefold increase in energy density per unit area. The dynamic simulations further show that the system can rapidly change its power output allowing it to provide frequency regulation services. Allocating 20% of its nominal power as a reserve, the new power setpoints can be reached within a maximum of 5 s independent of its initial state of charge.

IET Renewable Power GenerationVol. 18(S1)
Ghent University (BE), Chalmers University of Technology (SE), Delft University of Technology (NL)
European Commission, National Science Council, Vetenskapsrådet
Affordable and clean energy
Openalex Percentile: Top 15%
Microgrid Control and Optimization
1.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.