Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>E</mml:mi> <mml:mo>×</mml:mo> <mml:mi>B</mml:mi> </mml:mrow> </mml:math> drift technique (of a $$\sim $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>∼</mml:mo> </mml:math> 2– $$\upmu $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

Authors

Institutions

Publication Details

Journal
The European Physical Journal D
Published
2024-12-01
DOI
https://doi.org/10.1140/epjd/s10053-024-00821-x
Citations
2
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

T. S. Pedersen, Jens von der Linden, S. Nißl, H. Saitoh et al.
2 citations
The European Physical Journal D
Particle accelerators and beam dynamics
2.60
article

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

T. S. Pedersen, Jens von der Linden, S. Nißl, H. Saitoh, Christoph Hugenschmidt, Nathan Belmore, A. Deller, E. V. Stenson, M. Singer
article en
2 citations

Abstract

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>E</mml:mi> <mml:mo>×</mml:mo> <mml:mi>B</mml:mi> </mml:mrow> </mml:math> drift technique (of a $$\sim $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>∼</mml:mo> </mml:math> 2– $$\upmu $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

The European Physical Journal DVol. 78(12)
University of California San Diego (US), Madison Group (United States) (US), Kavli Institute for the Physics and Mathematics of the Universe (JP), Max Planck Institute for Plasma Physics - Greifswald (DE), Energy Center of Wisconsin (US), Kennisland (NL), Max Planck Institute for Plasma Physics (DE), Applied Materials (Germany) (DE), Technical University of Munich (DE), The University of Tokyo (JP)
U.S. Department of Energy, Alexander von Humboldt-Stiftung, European Commission, Deutsche Forschungsgemeinschaft, Helmholtz Association, University of California, San Diego, H2020 European Research Council
Openalex Percentile: Top 8%
Particle accelerators and beam dynamics
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.