Non-Unit Transient Protection for LCC-HVDC Transmission Lines Based on Correlation of Current Derivatives

The reliability and sensitivity of HVDC transmission line's protection for HVDC system are in need of further improvement. So a new non-unit transient protection based on correlation of current derivatives (CDs) is proposed in this paper. According to the impedance frequency characteristics of converter and DC filter, the correlation characteristics between line current derivative (LCD) and DC filter current derivative (DFCD) are analyzed during fault transients. Simulation results show that the proposed protection scheme can correctly identify internal and external faults and is of high reliability and sensitivity.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768336
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Unit Transient Protection for LCC-HVDC Transmission Lines Based on Correlation of Current Derivatives

Jinzhao Song, Yi Yang, Luoluo Wang, Yunke Zhang et al.
HVDC Systems and Fault Protection
article

Non-Unit Transient Protection for LCC-HVDC Transmission Lines Based on Correlation of Current Derivatives

Jinzhao Song, Yi Yang, Luoluo Wang, Yunke Zhang, Siwei Li, Huihua Huang, Zengyuan Tian, Z. Luo
article en

Abstract

The reliability and sensitivity of HVDC transmission line's protection for HVDC system are in need of further improvement. So a new non-unit transient protection based on correlation of current derivatives (CDs) is proposed in this paper. According to the impedance frequency characteristics of converter and DC filter, the correlation characteristics between line current derivative (LCD) and DC filter current derivative (DFCD) are analyzed during fault transients. Simulation results show that the proposed protection scheme can correctly identify internal and external faults and is of high reliability and sensitivity.

Tianjin Research Institute of Electric Science (China) (CN)
Openalex Percentile: Top 80%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.