Low-Voltage Regulation Device Based on IGBT Combination Switches

With the rapid development of the economy in rural areas, the residents of the stable reliability of the power supply has put forward higher requirements, but due to the agricultural network has a long transmission radius, weak network structure and other characteristics, resulting in the existence of serious low voltage problems at the end of the line. This paper synthesizes the advantages and disadvantages of the existing low-voltage management technology, and puts forward a low-voltage management technology scheme based on IGBT combinational switch, which is connected to the end of the 10kV line through two transformers in series and parallel, and utilizes the IGBT combinational switch as a transformer tap casting and cutting device to control the regulation of line voltage. The principle analysis and simulink simulation model verification of the scheme, and through the parameter design to complete the prototype development, and finally the prototype test to verify the correctness and effectiveness of the scheme.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icpre62586.2024.10768446
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Voltage Regulation Device Based on IGBT Combination Switches

Shuhui Li, Zhuofan Wen, Shuping Zhuo, Xinwei Jiang et al.
Induction Heating and Inverter Technology
article

Low-Voltage Regulation Device Based on IGBT Combination Switches

Shuhui Li, Zhuofan Wen, Shuping Zhuo, Xinwei Jiang, Yang Zhang, Yihang Liu, Zeyi Zhu
article en

Abstract

With the rapid development of the economy in rural areas, the residents of the stable reliability of the power supply has put forward higher requirements, but due to the agricultural network has a long transmission radius, weak network structure and other characteristics, resulting in the existence of serious low voltage problems at the end of the line. This paper synthesizes the advantages and disadvantages of the existing low-voltage management technology, and puts forward a low-voltage management technology scheme based on IGBT combinational switch, which is connected to the end of the 10kV line through two transformers in series and parallel, and utilizes the IGBT combinational switch as a transformer tap casting and cutting device to control the regulation of line voltage. The principle analysis and simulink simulation model verification of the scheme, and through the parameter design to complete the prototype development, and finally the prototype test to verify the correctness and effectiveness of the scheme.

Jiangxi University of Water Resources and Electric Power (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 78%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.