Clinical Applicability of 2‐Field High‐Resolution and Extended <scp>HLA</scp>‐Allele Typing in Deceased Donor Kidney Allocation

ABSTRACT HLA‐compatibility remains an important triage test for deceased donor kidney allocation. Low–intermediate resolution donor HLA‐typing is typically available at allocation, but its accuracy in assigning pre‐transplant donor‐specific anti‐HLA antibody (DSA) and HLA mismatches compared to 2‐field high‐resolution typing is poorly characterised. Consecutive deceased donor/recipient pairs from a single centre between 2016 and 2020 were included. Majority of donor typing at HLA‐ABDRB1 loci were performed at low–intermediate resolution, with 2‐field high‐resolution NGS typing across extended loci performed by NGS‐technique post‐transplantation. We compared the two typing methods for (1) accuracy of pre‐transplant DSA assignment; (2) misassignment of HLA‐antigen/allele mismatches and performance of each model for acute rejection and (3) proportion of recipients who developed de novo DSA (dnDSA) when matched at antigen but mismatched at allele level. Of 179 deceased donor/recipient pairs, 157 donors had low–intermediate resolution typing and 22 with high‐resolution ONT typing. Sixty‐two recipients (35%) had potential pre‐transplant DSAs, with incorrect assignment of allele‐specific Class I and II actual DSAs in 31% and 53% of cases, respectively. NGS typing identified 59 (33%) additional HLA‐DRB1 allele mismatches. ONT typing accurately assigned pre‐transplant DSAs and allele mismatches in all cases. Seven (4%) recipients with antigen/allele level discordance developed dnDSAs, majority HLA‐DQ antibodies. Two‐field high‐resolution donor HLA typing may provide a more accurate transplant immunological risk assessment and identify those at risk of developing dnDSA to matched HLA antigen.

Authors

Institutions

Publication Details

Journal
HLA
Published
2024-12-01
DOI
https://doi.org/10.1111/tan.15784
Citations
2
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
1.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Applicability of 2‐Field High‐Resolution and Extended HLA‐Allele Typing in Deceased Donor Kidney Allocation

Ankit Sharma, Nicholas Larkins, Aron Chakera, Armando Teixeira‐Pinto et al.
2 citations
HLA
Renal Transplantation Outcomes and Treatments
1.02
article

Clinical Applicability of 2‐Field High‐Resolution and Extended HLA‐Allele Typing in Deceased Donor Kidney Allocation

Ankit Sharma, Nicholas Larkins, Aron Chakera, Armando Teixeira‐Pinto, Ryan Gately, Lloyd D’Orsogna, Germaine Wong, Jonathan Downing, A. Taverniti, Wai H. Lim, Matthew Chau, Esther Ooi, Farzaneh Boroumand, Pedro López, Anoushka Krishnan, Doris Chan, Zhan Lim, Cindy Le
article en
2 citations

Abstract

ABSTRACT HLA‐compatibility remains an important triage test for deceased donor kidney allocation. Low–intermediate resolution donor HLA‐typing is typically available at allocation, but its accuracy in assigning pre‐transplant donor‐specific anti‐HLA antibody (DSA) and HLA mismatches compared to 2‐field high‐resolution typing is poorly characterised. Consecutive deceased donor/recipient pairs from a single centre between 2016 and 2020 were included. Majority of donor typing at HLA‐ABDRB1 loci were performed at low–intermediate resolution, with 2‐field high‐resolution NGS typing across extended loci performed by NGS‐technique post‐transplantation. We compared the two typing methods for (1) accuracy of pre‐transplant DSA assignment; (2) misassignment of HLA‐antigen/allele mismatches and performance of each model for acute rejection and (3) proportion of recipients who developed de novo DSA (dnDSA) when matched at antigen but mismatched at allele level. Of 179 deceased donor/recipient pairs, 157 donors had low–intermediate resolution typing and 22 with high‐resolution ONT typing. Sixty‐two recipients (35%) had potential pre‐transplant DSAs, with incorrect assignment of allele‐specific Class I and II actual DSAs in 31% and 53% of cases, respectively. NGS typing identified 59 (33%) additional HLA‐DRB1 allele mismatches. ONT typing accurately assigned pre‐transplant DSAs and allele mismatches in all cases. Seven (4%) recipients with antigen/allele level discordance developed dnDSAs, majority HLA‐DQ antibodies. Two‐field high‐resolution donor HLA typing may provide a more accurate transplant immunological risk assessment and identify those at risk of developing dnDSA to matched HLA antigen.

HLAVol. 104(6)
Edith Cowan University (AU), The University of Sydney (AU), The University of Western Australia (AU), Royal Perth Hospital (AU), Harry Perkins Institute of Medical Research (AU), Princess Margaret Hospital for Children (AU), Fiona Stanley Hospital (AU), Government of Western Australia Department of Health (AU), Princess Alexandra Hospital (AU), Sir Charles Gairdner Hospital (AU), Children's Hospital at Westmead (AU), Westmead Hospital (AU), Universidade de Caxias do Sul (BR), Institute for Respiratory Health (AU), Perth Children's Hospital, Macquarie University (AU)
Openalex Percentile: Top 22%
Renal Transplantation Outcomes and Treatments
1.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.