Smartcytoflow: A Machine Learning Decision Support System for Flow Cytometry Analysis in Multiple Myeloma Diagnosis and Monitoring

Introduction Monoclonal gammopathies, particularly multiple myeloma (MM), pose significant diagnostic challenges due to their complex cellular profiles. Flow cytometry, enhanced by EuroFlow standards, offers a detailed analysis but remains labor-intensive and prone to inter-observer variability. Machine learning can streamline this process, providing consistent and accurate diagnostic support. This study explores the application of machine learning to flow cytometry data for the diagnosis and minimal residual disease (MRD) detection in MM. Objectives The primary objective was to develop and validate a machine learning model for the accurate diagnosis and MRD detection in MM using flow cytometry data. Secondary objectives included balancing the dataset, improving plasma cell enrichment, and evaluating the model's performance in a clinical setting. Methodology We collected over 800 samples studied according to EuroFlow standards for MM, which included two different tubes: the first tube comprising CD138, CD38, CD45, CD19, CD56, CD27, CD117, CD81, CD20, CD200, CD28, and cytoplasmic immunoglobulin kappa/lambda, and the second tube comprising CD138, CD38, CD45, CD19, CD56, CD27, CD117, CD81, CD20, CD200, CD28, and cytoplasmic immunoglobulin kappa/lambda. Among these, 44% of the samples were for diagnosis purposes and 56% for MRD detection, with 90% of diagnostic samples confirmed as pathogenic by expert review. Preprocessing included using the Bioconductor package flowAI to remove doublets, margins, and artifacts. A gating strategy was applied to enrich the analysis for plasma cells, extracting only positive events from each sample. To address dataset imbalances, we applied the Synthetic Minority Over-sampling Technique (SMOTE) in the training set. We employed flowSOM for clustering, extracting clusters and metaclusters from each tube, which were then fed into a random forest classifier. The model was trained and cross-validated in the training set, followed by independent validation in the test set. Results The training set comprised 1,000 samples with an equal distribution of class labels (500 positive, 500 negative). The random forest model exhibited robust performance during the training phase, achieving an out-of-bag (OOB) area under the curve (AUC) of 99.3%, a precision-recall (PR) AUC of 99.3%, and a Brier score of 0.04, indicating high accuracy. The OOB G-mean was 0.95, with a misclassification rate of 4.8%. The confusion matrix indicated a class error of 1.2% for the negative class and 8.4% for the positive class. The test set consisted of 138 samples. During the validation phase, the model maintained strong performance, with an AUC of 91.6%, a PR-AUC of 0.72, and a Brier score of 0.10. The G-mean for the test set was 0.91, with a misclassification rate of 10.9%. The confusion matrix for the test set showed a class error of 2.3% for the negative class and 14.7% for the positive class. Further analysis of the test set revealed that 56 samples were diagnostic, with a misclassification rate of 5%, while 82 samples were obtained for MRD detection, where the rate increased to 13.58%. In addition to the robust performance metrics, the implementation of our machine learning model within the SmartCytoFlow platform has significantly streamlined the diagnostic workflow. SmartCytoFlow automates data preprocessing, gating, clustering, and classification, providing real-time diagnostic support. The integration has resulted in a substantial reduction in analysis time and improved diagnostic consistency. Conclusion Our study underscores the efficacy of integrating machine learning with flow cytometry for diagnosing and monitoring of monoclonal gammopathies, and particularly multiple myeloma. This approach offers a promising adjunct to traditional diagnostic methods, ensuring consistency and accuracy in clinical settings. Future validation in diverse cohorts is warranted to establish its broader applicability and utility in routine diagnostic practice.

Authors

Institutions

Publication Details

Journal
Blood
Published
2024-11-05
DOI
https://doi.org/10.1182/blood-2024-194599
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartcytoflow: A Machine Learning Decision Support System for Flow Cytometry Analysis in Multiple Myeloma Diagnosis and Monitoring

Davide Crucitti, Carlos Pérez Míguez, M. Isabel Fiel, Marta Sonia González et al.
Blood
Digital Imaging for Blood Diseases
article

Smartcytoflow: A Machine Learning Decision Support System for Flow Cytometry Analysis in Multiple Myeloma Diagnosis and Monitoring

Davide Crucitti, Carlos Pérez Míguez, M. Isabel Fiel, Marta Sonia González, Jesús Gómez Fernández, José Ángel Díaz Arias, Adrián Mosquera Orgueira, María-Victoria Mateos
article en

Abstract

Introduction Monoclonal gammopathies, particularly multiple myeloma (MM), pose significant diagnostic challenges due to their complex cellular profiles. Flow cytometry, enhanced by EuroFlow standards, offers a detailed analysis but remains labor-intensive and prone to inter-observer variability. Machine learning can streamline this process, providing consistent and accurate diagnostic support. This study explores the application of machine learning to flow cytometry data for the diagnosis and minimal residual disease (MRD) detection in MM. Objectives The primary objective was to develop and validate a machine learning model for the accurate diagnosis and MRD detection in MM using flow cytometry data. Secondary objectives included balancing the dataset, improving plasma cell enrichment, and evaluating the model's performance in a clinical setting. Methodology We collected over 800 samples studied according to EuroFlow standards for MM, which included two different tubes: the first tube comprising CD138, CD38, CD45, CD19, CD56, CD27, CD117, CD81, CD20, CD200, CD28, and cytoplasmic immunoglobulin kappa/lambda, and the second tube comprising CD138, CD38, CD45, CD19, CD56, CD27, CD117, CD81, CD20, CD200, CD28, and cytoplasmic immunoglobulin kappa/lambda. Among these, 44% of the samples were for diagnosis purposes and 56% for MRD detection, with 90% of diagnostic samples confirmed as pathogenic by expert review. Preprocessing included using the Bioconductor package flowAI to remove doublets, margins, and artifacts. A gating strategy was applied to enrich the analysis for plasma cells, extracting only positive events from each sample. To address dataset imbalances, we applied the Synthetic Minority Over-sampling Technique (SMOTE) in the training set. We employed flowSOM for clustering, extracting clusters and metaclusters from each tube, which were then fed into a random forest classifier. The model was trained and cross-validated in the training set, followed by independent validation in the test set. Results The training set comprised 1,000 samples with an equal distribution of class labels (500 positive, 500 negative). The random forest model exhibited robust performance during the training phase, achieving an out-of-bag (OOB) area under the curve (AUC) of 99.3%, a precision-recall (PR) AUC of 99.3%, and a Brier score of 0.04, indicating high accuracy. The OOB G-mean was 0.95, with a misclassification rate of 4.8%. The confusion matrix indicated a class error of 1.2% for the negative class and 8.4% for the positive class. The test set consisted of 138 samples. During the validation phase, the model maintained strong performance, with an AUC of 91.6%, a PR-AUC of 0.72, and a Brier score of 0.10. The G-mean for the test set was 0.91, with a misclassification rate of 10.9%. The confusion matrix for the test set showed a class error of 2.3% for the negative class and 14.7% for the positive class. Further analysis of the test set revealed that 56 samples were diagnostic, with a misclassification rate of 5%, while 82 samples were obtained for MRD detection, where the rate increased to 13.58%. In addition to the robust performance metrics, the implementation of our machine learning model within the SmartCytoFlow platform has significantly streamlined the diagnostic workflow. SmartCytoFlow automates data preprocessing, gating, clustering, and classification, providing real-time diagnostic support. The integration has resulted in a substantial reduction in analysis time and improved diagnostic consistency. Conclusion Our study underscores the efficacy of integrating machine learning with flow cytometry for diagnosing and monitoring of monoclonal gammopathies, and particularly multiple myeloma. This approach offers a promising adjunct to traditional diagnostic methods, ensuring consistency and accuracy in clinical settings. Future validation in diverse cohorts is warranted to establish its broader applicability and utility in routine diagnostic practice.

BloodVol. 144(Supplement 1)
Universidad de Salamanca (ES), Universidade de Santiago de Compostela (ES), Instituto de Investigación Sanitaria de Santiago (ES)
Openalex Percentile: Top 78%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.