Assessing the repeatability, reliability, and precision of right ventricular outflow tract and mid-pulmonary artery diameters, velocity time integrals, and agreement between site-specific stroke volumes
The RVOTD, MPAD, RVOTVTI, and MPAVTI measurements were repeatable, reliable, and precise. The agreement between RVOTSV and MPASV ranged from fair to excellent, although significant bias, along with a wide limit of agreement, was observed. Consequently, these methods cannot be used interchangeably.
Authors
- Reza Mohseni‐Badalabadi (ORCID: https://orcid.org/0000-0003-3135-8526)
- Ali Hosseinsabet (ORCID: https://orcid.org/0000-0003-2927-3742)
- Flora Fallah (ORCID: https://orcid.org/0009-0002-2283-9440)
- Reza Hali (ORCID: https://orcid.org/0000-0001-6502-5813)
- Leila Hosseininejad
Institutions
- Tehran University of Medical Sciences (IR)
- Shomal University (IR)
Publication Details
- Journal
- BMC Cardiovascular Disorders
- Published
- 2024-12-06
- DOI
- https://doi.org/10.1186/s12872-024-04384-y
- Primary Topic
- Pulmonary Hypertension Research and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00