Impact of macrohemodynamic manipulations during cardiopulmonary bypass on finger microcirculation assessed by photoplethysmography signal components
<i>Objective.</i>Continuous monitoring of the hemodynamic coherence between macro and microcirculation is difficult at the bedside. We tested the role of photoplethysmography (PPG) to real-time assessment of microcirculation during extreme manipulation of macrohemodynamics induced by the cardiopulmonary bypass (CPB).<i>Approach.</i>We analyzed the alternating (AC) and direct (DC) components of the finger PPG in 12 patients undergoing cardiac surgery with CPB at five moments: (1) before-CPB; (2) CPB-start, at the transition from pulsatile to non-pulsatile blood flow; (3) CPB-aortic clamping, at a sudden decrease in pump blood flow and volemia.; (4) CPB-weaning, during step-wise 20% decreases in pump blood flow and opposite proportional increases in native pulsatile blood flow; and (5) after-CPB.<i>Main results.</i>Nine Caucasian men and three women were included for analysis. Macrohemodynamic changes during CPB had an immediate impact on the PPG at all studied moments. Before-CPB the AC signal amplitude showed a median and IQR values of 0.0023(0.0013). The AC signal completely disappeared at CPB-start and at CPB-aortic clamping. During CPB weaning its amplitude progressively increased but remained lower than before CPB, at 80% [0.0008 (0.0005);<i>p</i>< 0.001], 60% [0.0010(0.0006);<i>p</i>< 0.001], and 40% [0.0013(0.0009);<i>p</i>= 0.011] of CPB flow. The AC amplitude returned close to Before-CPB values at 20% of CPB flow [0.0015(0.0008);<i>p</i>= 0.081], when CPB was completely stopped [0.0019 (0.0009);<i>p</i>= 0.348], and at after-CPB [0.0021(0.0009);<i>p</i>= 0.687]. The DC signal Before-CPB [0.95(0.02)] did not differ statistically from CPB-start, CPB-weaning and After-CPB. However, at CPB-aortic clamping, at no flow and a sudden drop in volemia, the DC signal decreased from [0.96(0.01)] to [0.94(0.02);<i>p</i>= 0.002].<i>Significance.</i>The macrohemodynamic alterations brought on by CPB were consistent with changes in the finger's microcirculation. PPG described local pulsatile blood flow (AC) as well as non-pulsatile blood flow and volemia (DC) in the finger. These findings provide plausibility to the use of PPG in ongoing hemodynamic coherence monitoring.
Authors
- Nora Fuentes (ORCID: https://orcid.org/0000-0002-4893-3374)
- Cecilia M. Acosta (ORCID: https://orcid.org/0000-0003-0063-6896)
- Fernando Suárez-Sipmann (ORCID: https://orcid.org/0000-0002-7412-2970)
- Gerardo Tusman (ORCID: https://orcid.org/0000-0003-3893-4418)
- Daniel Absi (ORCID: https://orcid.org/0000-0001-5282-2696)
- Stephan H. Böhm
- Juan Carlos Climente
Institutions
- Instituto de Salud Carlos III (ES)
- Hospital Privado de Comunidad (AR)
- Hospital Universitario de La Princesa (ES)
- University of Rostock (DE)
- Universidad Autónoma de Madrid (ES)
Publication Details
- Journal
- Physiological Measurement
- Published
- 2024-12-01
- DOI
- https://doi.org/10.1088/1361-6579/ad9af6
- Primary Topic
- Hemodynamic Monitoring and Therapy
- Type
- article
- Field-Weighted Citation Impact
- 0.00