Optimizing Radiation Protection in PET/CT Examinations: Reducing Occupational Exposure During Patient Positioning

Objectives The objective of this study was to evaluate the occupational radiation exposure of healthcare workers during positron emission tomography (PET)/CT examinations, focusing on patient positioning and assessing the effectiveness of different radiation protection measures. Methods Thirteen medical workers (physicians, radiological technologists, and nurses) performed PET/CT examinations on 86 patients at a major Japanese hospital from June to August 2019. Occupational doses were measured using a real-time semiconductor dosimeter: RaySafe i2 (Unfors RaySafe, Billdal, Sweden), recording the 1 cm dose equivalent (Hp(10)). Exposure during various tasks was assessed, and radiation protection measures were evaluated, including increasing the number of personnel during patient positioning, using a protective screen (3.0 mm lead equivalent; Kuraray Trading Co., Ltd., Osaka, Japan), and implementing remote patient positioning via the PET/CT operator console. Results Patient positioning and discharge (task 4) resulted in the highest occupational exposure, with a median Hp(10) of 0.66 μSv per event (interquartile range (IQR): 0.54-0.71 μSv). Increasing the number of staff during task 4 did not significantly reduce occupational dose (p=0.725). Using a protective screen reduced the median Hp(10) to 0.58 μSv per event (IQR: 0.51-0.80 μSv). Remote positioning via the operator console further reduced it to 0.49 μSv per event (IQR: 0.35-0.62 μSv), achieving a significant dose-reduction (p=0.016). The dose reduction rates were 23.7% for the protective screen and 35.5% for the operator console method. Conclusions Patient positioning is the primary source of occupational radiation exposure during PET/CT examinations. Remote positioning via the operator console significantly reduces occupational exposure and working time compared to other methods, providing an effective and cost-efficient radiation protection strategy that aligns with the As Low As Reasonably Practicable (ALARP) principle. Advances in knowledge This study demonstrates that remote patient positioning via the operator console is an effective, easily implementable radiation protection measure that enhances operational efficiency without additional costs, representing a valuable advancement in occupational safety during PET/CT examinations.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-12-03
DOI
https://doi.org/10.7759/cureus.75052
Citations
2
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Radiation Protection in PET/CT Examinations: Reducing Occupational Exposure During Patient Positioning

Keisuke Nagamoto, Shoji Kawano, Shun‐ichi Nihei, Nobuyoshi Yoshizuka
2 citations
Cureus
Radiation Dose and Imaging
0.81
article

Optimizing Radiation Protection in PET/CT Examinations: Reducing Occupational Exposure During Patient Positioning

Keisuke Nagamoto, Shoji Kawano, Shun‐ichi Nihei, Nobuyoshi Yoshizuka
article en
2 citations

Abstract

Objectives The objective of this study was to evaluate the occupational radiation exposure of healthcare workers during positron emission tomography (PET)/CT examinations, focusing on patient positioning and assessing the effectiveness of different radiation protection measures. Methods Thirteen medical workers (physicians, radiological technologists, and nurses) performed PET/CT examinations on 86 patients at a major Japanese hospital from June to August 2019. Occupational doses were measured using a real-time semiconductor dosimeter: RaySafe i2 (Unfors RaySafe, Billdal, Sweden), recording the 1 cm dose equivalent (Hp(10)). Exposure during various tasks was assessed, and radiation protection measures were evaluated, including increasing the number of personnel during patient positioning, using a protective screen (3.0 mm lead equivalent; Kuraray Trading Co., Ltd., Osaka, Japan), and implementing remote patient positioning via the PET/CT operator console. Results Patient positioning and discharge (task 4) resulted in the highest occupational exposure, with a median Hp(10) of 0.66 μSv per event (interquartile range (IQR): 0.54-0.71 μSv). Increasing the number of staff during task 4 did not significantly reduce occupational dose (p=0.725). Using a protective screen reduced the median Hp(10) to 0.58 μSv per event (IQR: 0.51-0.80 μSv). Remote positioning via the operator console further reduced it to 0.49 μSv per event (IQR: 0.35-0.62 μSv), achieving a significant dose-reduction (p=0.016). The dose reduction rates were 23.7% for the protective screen and 35.5% for the operator console method. Conclusions Patient positioning is the primary source of occupational radiation exposure during PET/CT examinations. Remote positioning via the operator console significantly reduces occupational exposure and working time compared to other methods, providing an effective and cost-efficient radiation protection strategy that aligns with the As Low As Reasonably Practicable (ALARP) principle. Advances in knowledge This study demonstrates that remote patient positioning via the operator console is an effective, easily implementable radiation protection measure that enhances operational efficiency without additional costs, representing a valuable advancement in occupational safety during PET/CT examinations.

CureusVol. 16(12)
University of Occupational and Environmental Health Japan (JP), Fukuoka University Hospital (JP)
Openalex Percentile: Top 24%
Radiation Dose and Imaging
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.