Optimization of Radiation Dose and Effective Dose for CT Pelvis Examinations in Main Hospitals in ALTaif Region

Introduction: CT scan is one of the medical imaging methods that irradiate patients with significant amounts of radiation. These amount of radiation doses must be well estimated if the imaging area is in part containing radiation-sensitive organs such as the pelvic area. Objectives: the objectives of the current study were to assess radiation dose during pelvis and Abdomen CT imaging and estimate the effective dose as well as to propose diagnostic reference level (DRL).Methodology: 200 adult patients irradiated in two major governmental hospital in Taif city, Saudi Arabia, patients’ demographic data from was collected such as weight, height, and age. Scanner specifications and scan parameters for each pelvis examination were recorded in special data collection sheet. Volume CT dose index (CTDIvol and dose length product (DLP) were utilized to estimate the radiation dose and effective dose. Microsoft Excel was used to analyse the data.Main Results: there was variation in scanning parameters among two hospitals under study and this result in variation in effective dose between two hospitals. The average DLP, CTDIvol and effective dose were 368.5, 390.7 mGy-cm,10.2,10.8 mGy and 7, 7.4 mSv for hospital one and two respectively. Conclusion: Based on the third quartile of DLP and CTDIw, the recommended DRL for both hospitals was 405 mGy-cm and 21.75 mGy, respectively. The findings revealed a reduced effective dose value when compared with previous studies.

Authors

Institutions

Publication Details

Journal
Journal of Ecohumanism
Published
2024-12-04
DOI
https://doi.org/10.62754/joe.v3i8.5076
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Radiation Dose and Effective Dose for CT Pelvis Examinations in Main Hospitals in ALTaif Region

Khaled Shaher AlQahtani, Fahad Mohammed Dhafiri, Khaled nami Al wathnani, Rami mohammed Alghamdi et al.
Journal of Ecohumanism
Radiation Dose and Imaging
article

Optimization of Radiation Dose and Effective Dose for CT Pelvis Examinations in Main Hospitals in ALTaif Region

Khaled Shaher AlQahtani, Fahad Mohammed Dhafiri, Khaled nami Al wathnani, Rami mohammed Alghamdi, Ahmed Yaseen Alghubayshi, Saif hassen Almalki, Abdulwahab Aali Aleyli, Ahmed Eid Alotaibi, Fahad Musilh Altowairqi, Mufleh Mohammed Al-Subaie, Waleed Saeed Alahmary
article en

Abstract

Introduction: CT scan is one of the medical imaging methods that irradiate patients with significant amounts of radiation. These amount of radiation doses must be well estimated if the imaging area is in part containing radiation-sensitive organs such as the pelvic area. Objectives: the objectives of the current study were to assess radiation dose during pelvis and Abdomen CT imaging and estimate the effective dose as well as to propose diagnostic reference level (DRL).Methodology: 200 adult patients irradiated in two major governmental hospital in Taif city, Saudi Arabia, patients’ demographic data from was collected such as weight, height, and age. Scanner specifications and scan parameters for each pelvis examination were recorded in special data collection sheet. Volume CT dose index (CTDIvol and dose length product (DLP) were utilized to estimate the radiation dose and effective dose. Microsoft Excel was used to analyse the data.Main Results: there was variation in scanning parameters among two hospitals under study and this result in variation in effective dose between two hospitals. The average DLP, CTDIvol and effective dose were 368.5, 390.7 mGy-cm,10.2,10.8 mGy and 7, 7.4 mSv for hospital one and two respectively. Conclusion: Based on the third quartile of DLP and CTDIw, the recommended DRL for both hospitals was 405 mGy-cm and 21.75 mGy, respectively. The findings revealed a reduced effective dose value when compared with previous studies.

Journal of EcohumanismVol. 3(8)
King Abdulaziz Hospital (SA)
Good health and well-being
Openalex Percentile: Top 61%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of Radiation Dose and Effective Dose for CT Pelvis Examinations in Main Hospitals in ALTaif Region — Khaled Shaher AlQahtani, Fahad Mohammed Dhafiri, et al. · Journal of Ecohumanism (2024) | TGRS Research Map | TGRS