Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution

Cone beam computed tomography (CBCT) images are convenient representations for obtaining information about patients' internal organs, but their lower image quality than those of treatment planning CT images constitutes an important shortcoming. Several proposed CBCT image-quality improvement methods based on deep learning require large amounts of training data. Our newly developed model using a super-resolution method, "one-shot" super-resolution (OSSR) based on the "zero-shot" super-resolution method, requires only small amounts of training data to improve CBCT image quality using only the target CBCT image and the paired treatment planning CT image. For this study, pelvic CBCT images and treatment planning CT images of 30 prostate cancer patients were used. We calculated the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) to evaluate image-quality improvement and normalized mutual information (NMI) as a quantitative evaluation of positional accuracy. Our proposed method can improve CBCT image quality without requiring large amounts of training data. After applying our proposed method, the resulting RMSE, PSNR, SSIM, and NMI between the CBCT images and the treatment planning CT images were as much as 0.86, 1.05, 1.03, and 1.31 times better than those obtained without using our proposed method. By comparison, CycleGAN exhibited values of 0.91, 1.03, 1.02, and 1.16. The proposed method achieved performance equivalent to that of CycleGAN, which requires images from approximately 30 patients for training. Findings demonstrated improvement of CBCT image quality using only the target CBCT images and the paired treatment planning CT images.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2024-12-04
DOI
https://doi.org/10.1007/s10278-024-01346-w
Citations
1
Primary Topic
Advanced Image Processing Techniques
Type
article
Field-Weighted Citation Impact
0.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution

Asuka Oyama, Shinobu Kumagai, J. Kotoku, Kenshiro Shiraishi et al.
1 citations
Journal of Imaging Informatics in Medicine
Advanced Image Processing Techniques
0.25
article

Cone Beam Computed Tomography Image-Quality Improvement Using “One-Shot” Super-resolution

Asuka Oyama, Shinobu Kumagai, J. Kotoku, Kenshiro Shiraishi, Takumasa Tsuji, Soichiro Yoshida, Mitsuki Hommyo
article en
1 citations

Abstract

Cone beam computed tomography (CBCT) images are convenient representations for obtaining information about patients' internal organs, but their lower image quality than those of treatment planning CT images constitutes an important shortcoming. Several proposed CBCT image-quality improvement methods based on deep learning require large amounts of training data. Our newly developed model using a super-resolution method, "one-shot" super-resolution (OSSR) based on the "zero-shot" super-resolution method, requires only small amounts of training data to improve CBCT image quality using only the target CBCT image and the paired treatment planning CT image. For this study, pelvic CBCT images and treatment planning CT images of 30 prostate cancer patients were used. We calculated the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) to evaluate image-quality improvement and normalized mutual information (NMI) as a quantitative evaluation of positional accuracy. Our proposed method can improve CBCT image quality without requiring large amounts of training data. After applying our proposed method, the resulting RMSE, PSNR, SSIM, and NMI between the CBCT images and the treatment planning CT images were as much as 0.86, 1.05, 1.03, and 1.31 times better than those obtained without using our proposed method. By comparison, CycleGAN exhibited values of 0.91, 1.03, 1.02, and 1.16. The proposed method achieved performance equivalent to that of CycleGAN, which requires images from approximately 30 patients for training. Findings demonstrated improvement of CBCT image quality using only the target CBCT images and the paired treatment planning CT images.

Journal of Imaging Informatics in MedicineVol. 38(4)
Teikyo University Hospital (JP), University of Tokyo Hospital (JP), Teikyo University (JP), The University of Osaka (JP)
Japan Society for the Promotion of Science, Japan Science and Technology Agency, Exploratory Research for Advanced Technology
Good health and well-being
Openalex Percentile: Top 44%
Advanced Image Processing Techniques
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.