Feasibility of relaxation along a fictitious field in the 2nd rotating frame (TRAFF2) mapping in the human myocardium at 3 T

Myocardial <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow> <mml:mrow><mml:mi>RAFF</mml:mi> <mml:mn>2</mml:mn></mml:mrow> </mml:msub> </mml:math> quantification at 3 T was successfully achieved in a single breath-hold with acceptable image quality, albeit with residual off-resonance artifacts. Nonetheless, preliminary clinical data indicate potential sensitivity of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow> <mml:mrow><mml:mi>RAFF</mml:mi> <mml:mn>2</mml:mn></mml:mrow> </mml:msub> </mml:math> mapping to myocardial infarction detection without the need for contrast agents, but off-resonance artifacts mitigation warrants further investigation.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2024-12-04
DOI
https://doi.org/10.3389/fcvm.2024.1373240
Citations
1
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of relaxation along a fictitious field in the 2nd rotating frame (TRAFF2) mapping in the human myocardium at 3 T

Iain Pierce, Lothar R. Schad, Qian Tao, Thomas A. Treibel et al.
1 citations
Frontiers in Cardiovascular Medicine
Cardiac Imaging and Diagnostics
0.40
article

Feasibility of relaxation along a fictitious field in the 2nd rotating frame (TRAFF2) mapping in the human myocardium at 3 T

Iain Pierce, Lothar R. Schad, Qian Tao, Thomas A. Treibel, Christian Nitsche, Yidong Zhao, Sebastian Weingärtner, Mehmet Akçakaya, João Tourais, George Thornton, Maša Božić‐Iven
article en
1 citations

Abstract

Myocardial <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow> <mml:mrow><mml:mi>RAFF</mml:mi> <mml:mn>2</mml:mn></mml:mrow> </mml:msub> </mml:math> quantification at 3 T was successfully achieved in a single breath-hold with acceptable image quality, albeit with residual off-resonance artifacts. Nonetheless, preliminary clinical data indicate potential sensitivity of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow> <mml:mrow><mml:mi>RAFF</mml:mi> <mml:mn>2</mml:mn></mml:mrow> </mml:msub> </mml:math> mapping to myocardial infarction detection without the need for contrast agents, but off-resonance artifacts mitigation warrants further investigation.

Frontiers in Cardiovascular MedicineVol. 11
University of Minnesota (US), Heidelberg University (DE), Barts Health NHS Trust (GB), University Hospital Heidelberg (DE), University Medical Centre Mannheim (DE), Resonance Research (United States) (US), University College London (GB), Delft University of Technology (NL)
Openalex Percentile: Top 32%
Cardiac Imaging and Diagnostics
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.