Development, characterisation, biocompatibility, and corrosion analysis of gadolinium and selenium doped bioactive glass surface coating for dental implants

This study aimed to develop novel gadolinium and selenium-doped bioactive glass (gsBG)-coated titanium dental implants and analyse their surface, chemical, corrosion, and biocompatibility properties. A sol-gel method was used to prepare gsBG by hydrolysing 45% tetraethyl orthosilicate (TEOS) in water with nitric acid, followed by adding calcium nitrate, sodium nitrate, orthophosphoric acid, gadolinium, and selenous acid. The mixture was stirred, dip-coated on titanium, and sintered at 400°C. The coating was characterised using Field Emission Scanning Electron Microscope (FE-SEM), Energy Dispersive X-ray (EDX), and Fourier Transform Infrared Spectroscopy (FTIR). Biocompatibility was tested with MG63 cells, comparing gsBG-coated (Group A) and bare titanium implants (Group B). Cell viability was assessed at 24, 48, 72, 96, and 120 hours. An unpaired student t-test was performed to statistically analyse the effect of both groups on cell viability at various time points. Corrosion resistance was analysed via impedance and polarisation in artificial saliva. The SEM, EDX, and FTIR analysis proved the successful coating of the gsBG surface on the titanium implant. Confocal analysis following cell culture showed excellent biocompatibility. No statistically significant difference was observed between Groups A and B, with a P >0.05 noted at all time points, suggesting that the developed implant coating was biocompatible as a bare titanium surface. Corrosion analysis revealed that the developed surface coating was thermodynamically stable with high corrosion resistance. The developed novel gsBG surface coating has shown great potential as an implant surface coating for better osseointegration outcomes and long-term implant success.

Authors

Institutions

Publication Details

Journal
Journal of Oral and Maxillofacial Surgery Medicine and Pathology
Published
2024-12-04
DOI
https://doi.org/10.1016/j.ajoms.2024.12.002
Citations
9
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
1.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development, characterisation, biocompatibility, and corrosion analysis of gadolinium and selenium doped bioactive glass surface coating for dental implants

Artak G. Heboyan, Saheb Ali, Pradeep Kumar Yadalam, Seyed Ali Mosaddad et al.
9 citations
Journal of Oral and Maxillofacial Surgery Medicine and Pathology
Bone Tissue Engineering Materials
1.66
article

Development, characterisation, biocompatibility, and corrosion analysis of gadolinium and selenium doped bioactive glass surface coating for dental implants

Artak G. Heboyan, Saheb Ali, Pradeep Kumar Yadalam, Seyed Ali Mosaddad, P Arumugam, V. Vamshi Ram
article en
9 citations

Abstract

This study aimed to develop novel gadolinium and selenium-doped bioactive glass (gsBG)-coated titanium dental implants and analyse their surface, chemical, corrosion, and biocompatibility properties. A sol-gel method was used to prepare gsBG by hydrolysing 45% tetraethyl orthosilicate (TEOS) in water with nitric acid, followed by adding calcium nitrate, sodium nitrate, orthophosphoric acid, gadolinium, and selenous acid. The mixture was stirred, dip-coated on titanium, and sintered at 400°C. The coating was characterised using Field Emission Scanning Electron Microscope (FE-SEM), Energy Dispersive X-ray (EDX), and Fourier Transform Infrared Spectroscopy (FTIR). Biocompatibility was tested with MG63 cells, comparing gsBG-coated (Group A) and bare titanium implants (Group B). Cell viability was assessed at 24, 48, 72, 96, and 120 hours. An unpaired student t-test was performed to statistically analyse the effect of both groups on cell viability at various time points. Corrosion resistance was analysed via impedance and polarisation in artificial saliva. The SEM, EDX, and FTIR analysis proved the successful coating of the gsBG surface on the titanium implant. Confocal analysis following cell culture showed excellent biocompatibility. No statistically significant difference was observed between Groups A and B, with a P >0.05 noted at all time points, suggesting that the developed implant coating was biocompatible as a bare titanium surface. Corrosion analysis revealed that the developed surface coating was thermodynamically stable with high corrosion resistance. The developed novel gsBG surface coating has shown great potential as an implant surface coating for better osseointegration outcomes and long-term implant success.

Journal of Oral and Maxillofacial Surgery Medicine and PathologyVol. 37(3)
Universidad Complutense de Madrid (ES), Yerevan State Medical University (AM), Saveetha University (IN)
Openalex Percentile: Top 17%
Bone Tissue Engineering Materials
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.