Non‐invasive point‐of‐care optical technique for continuous in vivo assessment of microcirculatory function: Application to a preclinical model of early sepsis

Increased amplitude of peripheral vasomotion is a potential early marker of sepsis-related microcirculatory impairment; however, previous reports relied on clinically unsuitable invasive techniques. Hyperspectral near-infrared spectroscopy (hsNIRS) and diffuse correlation spectroscopy (DCS) are non-invasive, bedside techniques that can be paired to continuously monitor tissue hemoglobin content (HbT), oxygenation (StO<sub>2</sub>), and perfusion (rBF) to detect vasomotion as low-frequency microhemodynamic oscillations. While previous studies have primarily focused on the peripheral microcirculation, cerebral injury is also a common occurrence in sepsis and hsNIRS-DCS could be used to assess cerebral microcirculatory function. This work aimed to use a hybrid hsNIRS-DCS system to continuously monitor changes in the peripheral and cerebral microcirculation in a rat model of early sepsis. It was hypothesized that the skeletal muscle would be a more sensitive early indicator of sepsis-related changes in microhemodynamics than the brain. Control animals received saline while the experimental group received fecal slurry to induce sepsis. Subsequently, hsNIRS-DCS measurements were acquired from the skeletal muscle and brain for 6 h. Peripheral rBF rapidly decreased in septic animals, but there were no significant changes in peripheral HbT or StO<sub>2</sub>, nor cerebral HbT, rBF, or StO<sub>2</sub>. The power of low-frequency peripheral oscillations in all parameters (i.e., HbT, StO<sub>2</sub>, and rBF) as well as cerebral HbT oscillations were elevated in septic animals during the final 4 h. These findings suggest that in the early stages of sepsis, while vital organs like the brain are partly protected, changes in peripheral perfusion and vasomotor activity can be detected using hsNIRS-DCS. Future work will apply the technique to ICU patients.

Authors

Institutions

Publication Details

Journal
The FASEB Journal
Published
2024-12-04
DOI
https://doi.org/10.1096/fj.202401889r
Citations
8
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
3.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non‐invasive point‐of‐care optical technique for continuous in vivo assessment of microcirculatory function: Application to a preclinical model of early sepsis

Christopher G. Ellis, Stephanie Milkovich, Rasa Eskandari, Farah Kamar et al.
8 citations
The FASEB Journal
Optical Imaging and Spectroscopy Techniques
3.23
article

Non‐invasive point‐of‐care optical technique for continuous in vivo assessment of microcirculatory function: Application to a preclinical model of early sepsis

Christopher G. Ellis, Stephanie Milkovich, Rasa Eskandari, Farah Kamar, Daniel Goldman, Donald Gordon Welsh, Mamadou Diop
article en
8 citations

Abstract

Increased amplitude of peripheral vasomotion is a potential early marker of sepsis-related microcirculatory impairment; however, previous reports relied on clinically unsuitable invasive techniques. Hyperspectral near-infrared spectroscopy (hsNIRS) and diffuse correlation spectroscopy (DCS) are non-invasive, bedside techniques that can be paired to continuously monitor tissue hemoglobin content (HbT), oxygenation (StO<sub>2</sub>), and perfusion (rBF) to detect vasomotion as low-frequency microhemodynamic oscillations. While previous studies have primarily focused on the peripheral microcirculation, cerebral injury is also a common occurrence in sepsis and hsNIRS-DCS could be used to assess cerebral microcirculatory function. This work aimed to use a hybrid hsNIRS-DCS system to continuously monitor changes in the peripheral and cerebral microcirculation in a rat model of early sepsis. It was hypothesized that the skeletal muscle would be a more sensitive early indicator of sepsis-related changes in microhemodynamics than the brain. Control animals received saline while the experimental group received fecal slurry to induce sepsis. Subsequently, hsNIRS-DCS measurements were acquired from the skeletal muscle and brain for 6 h. Peripheral rBF rapidly decreased in septic animals, but there were no significant changes in peripheral HbT or StO<sub>2</sub>, nor cerebral HbT, rBF, or StO<sub>2</sub>. The power of low-frequency peripheral oscillations in all parameters (i.e., HbT, StO<sub>2</sub>, and rBF) as well as cerebral HbT oscillations were elevated in septic animals during the final 4 h. These findings suggest that in the early stages of sepsis, while vital organs like the brain are partly protected, changes in peripheral perfusion and vasomotor activity can be detected using hsNIRS-DCS. Future work will apply the technique to ICU patients.

The FASEB JournalVol. 38(23)
Western University (CA), Lawson Health Research Institute (CA)
Canadian Institutes of Health Research
Openalex Percentile: Top 7%
Optical Imaging and Spectroscopy Techniques
3.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.