Pulse Ultrasound-Based Response Enhancement of a MOX Gas Sensor

In this work, a new method to enhance the sensing response of an ultrasonically catalyzed metal oxide gas sensor has been proposed and developed, in which pulse ultrasound is employed to enhance the redox reaction at the sensing surface. It is experimentally confirmed that with a proper pulse width, the negative effect of acoustic streaming on the ultrasonic enhancement process can be effectively suppressed. Comparing the steady responses of five target gases under the pulse and continuous ultrasound, respectively, it is found that the pulse ultrasound causes a better catalysis effect, and response enhancement (RE) by the pulse ultrasound with an optimal pulse width depends on the ultrasonic strength as well as the species and concentration of the target gas. For 2 ppm methanol, the RE by the pulse ultrasound is 50%, relative to the continuous ultrasound, when the pulse width, duty ratio, and working frequency are 0.4 ms, 50%, and 110.1 kHz, respectively. The optimal pulse width decreases when the ultrasonic strength increases and is not affected by the target gas species and concentration. The lower the target gas concentration, the larger the optimal RE caused by pulse ultrasound. Moreover, for a given pulse width, the interpulse time also affects the RE.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-12-04
DOI
https://doi.org/10.1021/acssensors.4c01548
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse Ultrasound-Based Response Enhancement of a MOX Gas Sensor

Junhui Hu, Yumin Yang
ACS Sensors
Advanced Chemical Sensor Technologies
article

Pulse Ultrasound-Based Response Enhancement of a MOX Gas Sensor

Junhui Hu, Yumin Yang
article en

Abstract

In this work, a new method to enhance the sensing response of an ultrasonically catalyzed metal oxide gas sensor has been proposed and developed, in which pulse ultrasound is employed to enhance the redox reaction at the sensing surface. It is experimentally confirmed that with a proper pulse width, the negative effect of acoustic streaming on the ultrasonic enhancement process can be effectively suppressed. Comparing the steady responses of five target gases under the pulse and continuous ultrasound, respectively, it is found that the pulse ultrasound causes a better catalysis effect, and response enhancement (RE) by the pulse ultrasound with an optimal pulse width depends on the ultrasonic strength as well as the species and concentration of the target gas. For 2 ppm methanol, the RE by the pulse ultrasound is 50%, relative to the continuous ultrasound, when the pulse width, duty ratio, and working frequency are 0.4 ms, 50%, and 110.1 kHz, respectively. The optimal pulse width decreases when the ultrasonic strength increases and is not affected by the target gas species and concentration. The lower the target gas concentration, the larger the optimal RE caused by pulse ultrasound. Moreover, for a given pulse width, the interpulse time also affects the RE.

ACS SensorsVol. 9(12)
Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 79%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.