Polymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission

Encapsulation of volatile organic compounds (VOCs) that could evaporate at a defined rate is of immense interest for application in emission reference materials (ERMs). Polyurethane/polyurea microcapsules with various VOC active ingredients (limonene, pinene, and toluene) were successfully produced by interfacial polymerization with Shirasu porous glass membrane emulsification in a size range between 10 and 50 μm. The effect of surfactant, VOC, monomer(s) type, and ratio has a great effect on the formulation process and morphology of capsules. The type of VOC played a significant role in the encapsulation efficiency. Due to the difference in vapor pressure and VOC/water interfacial tension, the formulation for encapsulation was optimized for each individual VOC. Furthermore, to achieve effective stability of the large droplets/capsules, a combination of ionic and nonionic surfactants was used. Optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA), were used to characterize the optimized microcapsules. The results showed that the obtained microcapsules exhibited a spherical shape and core-shell morphology and featured characteristic urethane-urea bonds. The amount of encapsulated VOC ranges between 54 and 7 wt %. The emission tests were performed with the help of the emission test chamber procedure (EN 16516). The limonene-loaded polyurethane/polyurea microcapsules show a change in emission rate of less than 10% within 14 days and can be considered as a potential candidate for use as an ERM.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-12-04
DOI
https://doi.org/10.1021/acsami.4c12826
Citations
3
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission

Anna Musyanovych, Mine Bílsel, Matthias Richter, Wolfgang Horn et al.
3 citations
ACS Applied Materials & Interfaces
Surface Modification and Superhydrophobicity
0.54
article

Polymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission

Anna Musyanovych, Mine Bílsel, Matthias Richter, Wolfgang Horn, Malín G. Lüdicke, Ali Enis Sadak, Christoph Grimmer, Lorenz Heßling
article en
3 citations

Abstract

Encapsulation of volatile organic compounds (VOCs) that could evaporate at a defined rate is of immense interest for application in emission reference materials (ERMs). Polyurethane/polyurea microcapsules with various VOC active ingredients (limonene, pinene, and toluene) were successfully produced by interfacial polymerization with Shirasu porous glass membrane emulsification in a size range between 10 and 50 μm. The effect of surfactant, VOC, monomer(s) type, and ratio has a great effect on the formulation process and morphology of capsules. The type of VOC played a significant role in the encapsulation efficiency. Due to the difference in vapor pressure and VOC/water interfacial tension, the formulation for encapsulation was optimized for each individual VOC. Furthermore, to achieve effective stability of the large droplets/capsules, a combination of ionic and nonionic surfactants was used. Optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA), were used to characterize the optimized microcapsules. The results showed that the obtained microcapsules exhibited a spherical shape and core-shell morphology and featured characteristic urethane-urea bonds. The amount of encapsulated VOC ranges between 54 and 7 wt %. The emission tests were performed with the help of the emission test chamber procedure (EN 16516). The limonene-loaded polyurethane/polyurea microcapsules show a change in emission rate of less than 10% within 14 days and can be considered as a potential candidate for use as an ERM.

ACS Applied Materials & InterfacesVol. 16(50)
Carl Zeiss (Germany) (DE), Federal Institute For Materials Research and Testing (DE), Fraunhofer Institute for Microengineering and Microsystems (DE), Tübitak National Metrology Institute (TR)
European Commission, Horizon 2020 Framework Programme, European Metrology Programme for Innovation and Research
Openalex Percentile: Top 37%
Surface Modification and Superhydrophobicity
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.