Renally Excretable Molybdenum Disulfide Nanoparticles as Contrast Agents for Dual-Energy Mammography and Computed Tomography

Compared with conventional mammography, contrast-enhanced dual-energy mammography (DEM) can improve tumor detection for people with dense breasts. However, currently available iodine-based contrast agents have several drawbacks such as their contraindication for use with renal insufficiency, high-dose requirement, and suboptimal contrast production. Molybdenum disulfide nanoparticles (MoS<sub>2</sub> NPs) have been shown to attenuate X-rays due to molybdenum's relatively high atomic number while having good biocompatibility. However, work exploring their use as X-ray contrast agents has been limited. In this study, we have developed a novel aqueous synthesis yielding ultrasmall, 2 nm MoS<sub>2</sub> NPs with various small molecule coatings, including glutathione (GSH), penicillamine, and 2-mercaptopropionic acid (2MPA). These nanoparticles were shown to have low in vitro cytotoxicity when tested with various cell lines at concentrations up to 1 mg/mL. For the first time, these particles were shown to generate clinically relevant contrast in DEM. In DEM, MoS<sub>2</sub> NPs generated higher contrast than iopamidol, a commercially available X-ray contrast agent, while also generating substantial contrast in CT. Moreover, MoS<sub>2</sub> NPs demonstrated rapid elimination in vivo, mitigating long-term toxicity concerns. Together, the results presented here suggest the potential utility of MoS<sub>2</sub> NPs as a dual-modality X-ray contrast agent for DEM and CT.

Authors

Institutions

Publication Details

Journal
Bioconjugate Chemistry
Published
2024-12-04
DOI
https://doi.org/10.1021/acs.bioconjchem.4c00508
Citations
3
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Renally Excretable Molybdenum Disulfide Nanoparticles as Contrast Agents for Dual-Energy Mammography and Computed Tomography

Derick Rosario, David P. Cormode, Xingjian Zhong, Lenitza M. Nieves et al.
3 citations
Bioconjugate Chemistry
Advanced X-ray and CT Imaging
0.55
article

Renally Excretable Molybdenum Disulfide Nanoparticles as Contrast Agents for Dual-Energy Mammography and Computed Tomography

Derick Rosario, David P. Cormode, Xingjian Zhong, Lenitza M. Nieves, Priyash Singh, Andrew D. A. Maidment, Katherine J. Mossburg, Kristen C. Lau, Emily K. Berkow, Nathaniel H. O
article en
3 citations

Abstract

Compared with conventional mammography, contrast-enhanced dual-energy mammography (DEM) can improve tumor detection for people with dense breasts. However, currently available iodine-based contrast agents have several drawbacks such as their contraindication for use with renal insufficiency, high-dose requirement, and suboptimal contrast production. Molybdenum disulfide nanoparticles (MoS<sub>2</sub> NPs) have been shown to attenuate X-rays due to molybdenum's relatively high atomic number while having good biocompatibility. However, work exploring their use as X-ray contrast agents has been limited. In this study, we have developed a novel aqueous synthesis yielding ultrasmall, 2 nm MoS<sub>2</sub> NPs with various small molecule coatings, including glutathione (GSH), penicillamine, and 2-mercaptopropionic acid (2MPA). These nanoparticles were shown to have low in vitro cytotoxicity when tested with various cell lines at concentrations up to 1 mg/mL. For the first time, these particles were shown to generate clinically relevant contrast in DEM. In DEM, MoS<sub>2</sub> NPs generated higher contrast than iopamidol, a commercially available X-ray contrast agent, while also generating substantial contrast in CT. Moreover, MoS<sub>2</sub> NPs demonstrated rapid elimination in vivo, mitigating long-term toxicity concerns. Together, the results presented here suggest the potential utility of MoS<sub>2</sub> NPs as a dual-modality X-ray contrast agent for DEM and CT.

Bioconjugate ChemistryVol. 35(12)
Saint Joseph's University (US), University of Pennsylvania (US)
University of Pennsylvania, National Institutes of Health, National Cancer Institute, National Institute of Biomedical Imaging and Bioengineering
Affordable and clean energy
Openalex Percentile: Top 36%
Advanced X-ray and CT Imaging
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.