The Energy Consumption Comparison of Temperature Difference-based Defrosting Exit Method and Time-based Defrosting Exit Method with Various Static Pressure Differences

The time-based defrosting exit method(TDEM) has been widely used in cold storage, but the issue of energy consumption has been heavily criticized. In this paper, a temperature difference-based defrosting exit method(TDDEM) is proposed to compare with TDEM. Firstly, a parameter acquisition system of cold storage is constructed, and the experimental setup is conducted to determine the experimental parameters. Subsequentially, the range of defrosting static pressure difference is determined based on pre-frosting experiment, and the defrosting experiment of TDEM and TDDEM are carried out at five various static pressure difference conditions, 16Pa, 14Pa, 12Pa, 10Pa and 8Pa, respectively. The results show that the temperature fluctuations per defrosting events of TDEM are more severe compared to TDDEM, with with average increases of 102.2%, 91.6%, 59.3%, and 46.5%, respectively. Energy consumptions of TDDEM are markedly lower than TDEM, with reductions of 21.4%, 15.7%, 14.09% and 14.59%, respectively. Whether TDEM or TDDEM, the lowest energy consumption is occurred at 10Pa, and highest is 8Pa.

Authors

Institutions

Publication Details

Journal
Journal of Solar Energy Research Updates
Published
2024-12-04
DOI
https://doi.org/10.31875/2410-2199.2024.11.08
Primary Topic
Food Supply Chain Traceability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Energy Consumption Comparison of Temperature Difference-based Defrosting Exit Method and Time-based Defrosting Exit Method with Various Static Pressure Differences

Yong Wan, Yufan Wu, Chao Li, Xu Wenjuan et al.
Journal of Solar Energy Research Updates
Food Supply Chain Traceability
article

The Energy Consumption Comparison of Temperature Difference-based Defrosting Exit Method and Time-based Defrosting Exit Method with Various Static Pressure Differences

Yong Wan, Yufan Wu, Chao Li, Xu Wenjuan, Zhao Yiji, Song Zilong
article en

Abstract

The time-based defrosting exit method(TDEM) has been widely used in cold storage, but the issue of energy consumption has been heavily criticized. In this paper, a temperature difference-based defrosting exit method(TDDEM) is proposed to compare with TDEM. Firstly, a parameter acquisition system of cold storage is constructed, and the experimental setup is conducted to determine the experimental parameters. Subsequentially, the range of defrosting static pressure difference is determined based on pre-frosting experiment, and the defrosting experiment of TDEM and TDDEM are carried out at five various static pressure difference conditions, 16Pa, 14Pa, 12Pa, 10Pa and 8Pa, respectively. The results show that the temperature fluctuations per defrosting events of TDEM are more severe compared to TDDEM, with with average increases of 102.2%, 91.6%, 59.3%, and 46.5%, respectively. Energy consumptions of TDDEM are markedly lower than TDEM, with reductions of 21.4%, 15.7%, 14.09% and 14.59%, respectively. Whether TDEM or TDDEM, the lowest energy consumption is occurred at 10Pa, and highest is 8Pa.

Journal of Solar Energy Research UpdatesVol. 11
Chengdu University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 74%
Food Supply Chain Traceability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.