CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS

An urgent practical task is to ensure the serviceability and safety of complex technical and information systems by monitoring their current states. Additionally, an important task is to use control charts to automatically detect the moment when certain limit states are exceeded by the characteristic features (parameters) of the technological process. In practice, it is quite common for characteristic features to be correlated. The presence of correlation affects the effectiveness of control charts in determining the moment of process disruption. The study objective is to compare the effectiveness of using different control chart types to control a correlated parameter process. The following control charts were studied: Shewhart, Hotelling, and modified Shewhart charts − principal component charts. Numerical modeling of a two-parameter process was conducted with the introduction of a non-random change in one of them at two control points, i.e., the process disorder was modeled at the appropriate time points. Subsequently, statistical studies of the modeled process were conducted using three types of control charts. The results revealed that the Shewhart charts did not reveal any process disruption, which is explained by the correlation of the parameters. Hotelling charts revealed a processing disorder at two points, but they do not indicate the cause of the disorder. The calculated partial Hotelling criterion did not indicate the cause of the disorder. The principal component charts revealed both the presence of a process disorder in two points and identified which parameter caused the disorder. This result demonstrates the effectiveness of principal component charts in detecting process disorder with correlated parameters, as well as their superiority over other charts that were studied. In addition, with an increase in the number of parameters, this method becomes even more effective, as it allows to reduce the number of parameters studied while maintaining their statistical significance. Keywords: effectiveness of control charts, Shewhart charts, Hotelling charts, principal components, statistical quality control, correlation of parameters.

Authors

Publication Details

Journal
System Research in Energy
Published
2024-11-29
DOI
https://doi.org/10.15407/srenergy2024.04.077
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS

Yevhen Volodarskyi, Oleh Kozyr
System Research in Energy
Engineering Diagnostics and Reliability
article

CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS

Yevhen Volodarskyi, Oleh Kozyr
article en

Abstract

An urgent practical task is to ensure the serviceability and safety of complex technical and information systems by monitoring their current states. Additionally, an important task is to use control charts to automatically detect the moment when certain limit states are exceeded by the characteristic features (parameters) of the technological process. In practice, it is quite common for characteristic features to be correlated. The presence of correlation affects the effectiveness of control charts in determining the moment of process disruption. The study objective is to compare the effectiveness of using different control chart types to control a correlated parameter process. The following control charts were studied: Shewhart, Hotelling, and modified Shewhart charts − principal component charts. Numerical modeling of a two-parameter process was conducted with the introduction of a non-random change in one of them at two control points, i.e., the process disorder was modeled at the appropriate time points. Subsequently, statistical studies of the modeled process were conducted using three types of control charts. The results revealed that the Shewhart charts did not reveal any process disruption, which is explained by the correlation of the parameters. Hotelling charts revealed a processing disorder at two points, but they do not indicate the cause of the disorder. The calculated partial Hotelling criterion did not indicate the cause of the disorder. The principal component charts revealed both the presence of a process disorder in two points and identified which parameter caused the disorder. This result demonstrates the effectiveness of principal component charts in detecting process disorder with correlated parameters, as well as their superiority over other charts that were studied. In addition, with an increase in the number of parameters, this method becomes even more effective, as it allows to reduce the number of parameters studied while maintaining their statistical significance. Keywords: effectiveness of control charts, Shewhart charts, Hotelling charts, principal components, statistical quality control, correlation of parameters.

System Research in EnergyVol. 2024(4)
Openalex Percentile: Top 76%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS — Yevhen Volodarskyi, Oleh Kozyr · System Research in Energy (2024) | TGRS Research Map | TGRS