ANALYSIS OF THE EFFECTS OF SELECTED QUANTITIES ON THE FOULING OF NATURAL GAS COOLER PIPES

In this article, the effects of selected quantities on the thickness of a fouling layer that is formed on the internal surface of the pipes of natural gas (NG) coolers are discussed. Models created by applying an analytical method, a dimensional analysis, and a multiple linear regression were compared. The most complex model was the analytical model with a total of 16 relevant physical quantities. From the practicality point of view, that model was very complicated since it required applying the iterative process. The dimensional model comprised 6 similarity criteria. The difference between the fouling layer thicknesses identified analytically and those identified using a model based on a dimensional analysis did not exceed 3.06 %. Out of the total number of relevant quantities, only those that had the strongest effects on the fouling layer thickness were selected with the use of MinitabX software. Three regression models, containing 6, 5, and 4 variables, were thus created. The difference between the results obtained from the simplest regression model and the values obtained from the dimensional model amounted to a maximum of 3.20 %. The use of the presented regression models in technical practice may be recommended.

Authors

Publication Details

Journal
MM Science Journal
Published
2024-12-04
DOI
https://doi.org/10.17973/mmsj.2024_12_2024044
Primary Topic
Mechanical and Thermal Properties Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF THE EFFECTS OF SELECTED QUANTITIES ON THE FOULING OF NATURAL GAS COOLER PIPES

Mária Čarnogurská, Natália Jasminská, Miriam Andrejiová, Miroslav Příhoda et al.
MM Science Journal
Mechanical and Thermal Properties Analysis
article

ANALYSIS OF THE EFFECTS OF SELECTED QUANTITIES ON THE FOULING OF NATURAL GAS COOLER PIPES

Mária Čarnogurská, Natália Jasminská, Miriam Andrejiová, Miroslav Příhoda, Marian V. Lazar, PETER CURMA
article en

Abstract

In this article, the effects of selected quantities on the thickness of a fouling layer that is formed on the internal surface of the pipes of natural gas (NG) coolers are discussed. Models created by applying an analytical method, a dimensional analysis, and a multiple linear regression were compared. The most complex model was the analytical model with a total of 16 relevant physical quantities. From the practicality point of view, that model was very complicated since it required applying the iterative process. The dimensional model comprised 6 similarity criteria. The difference between the fouling layer thicknesses identified analytically and those identified using a model based on a dimensional analysis did not exceed 3.06 %. Out of the total number of relevant quantities, only those that had the strongest effects on the fouling layer thickness were selected with the use of MinitabX software. Three regression models, containing 6, 5, and 4 variables, were thus created. The difference between the results obtained from the simplest regression model and the values obtained from the dimensional model amounted to a maximum of 3.20 %. The use of the presented regression models in technical practice may be recommended.

MM Science JournalVol. 2024(6)
Openalex Percentile: Top 78%
Mechanical and Thermal Properties Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.