Electromyographic Comparison of Traditional Fitness Machines, Outdoor Fitness Equipment Without Load Selectors, and Outdoor Fitness Equipment with Load Selectors in a Seated Chest Press Exercise in Trained Young Men

Outdoor fitness equipment (OFE) are strength training installations comparable to those found in indoor gyms but are located outdoors with greater accessibility. However, the scientific evidence supporting their effectiveness remains limited. The objective of this study was to analyze and compare the electromyographic (EMG) activity of upper limb muscle groups during the use of a traditional seated chest press (SCP) machine, a classic OFE SCP (OFE-SCP), and a new OFE-SCP featuring a load selector system (BIOFIT-SCP). The sample was composed of 34 active young men. EMG activity of five muscle groups was analyzed: the anterior deltoid (AD), the clavicular (CP) and sternal (SP) heads of the pectoralis major, and the lateral (LHTB) and long heads of the triceps brachii (LongHTB), under different intensities. The OFE-SCP showed significantly lower EMG activity compared with the SCP and BIOFIT-SCP in all muscles and phases (<i>p</i> < 0.001). Significantly lower EMG activity for the SP in all three phases was found on the BIOFIT-SCP compared with the SCP (<i>p</i> < 0.001), but it was significantly higher for the LHTB and AD in the BIOFIT-SCP compared with the SCP during the full and concentric phases (<i>p</i> < 0.05 to <i>p</i> < 0.001). In conclusion, training with the OFE-SCP generates less EMG activity than traditional machine training, while, in general, BIOFIT-SCP proved effective for strength training comparable to the SCP.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-03
DOI
https://doi.org/10.3390/s24237740
Citations
1
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromyographic Comparison of Traditional Fitness Machines, Outdoor Fitness Equipment Without Load Selectors, and Outdoor Fitness Equipment with Load Selectors in a Seated Chest Press Exercise in Trained Young Men

Pablo Jorge Marcos-Pardo, Alejandro Espeso-García, Noelia González-Gálvez, Tomás Abelleira-Lamela et al.
1 citations
Sensors
Sports Performance and Training
0.48
article

Electromyographic Comparison of Traditional Fitness Machines, Outdoor Fitness Equipment Without Load Selectors, and Outdoor Fitness Equipment with Load Selectors in a Seated Chest Press Exercise in Trained Young Men

Pablo Jorge Marcos-Pardo, Alejandro Espeso-García, Noelia González-Gálvez, Tomás Abelleira-Lamela, Francisco Esparza-Ros, Raquel Vaquero‐Cristóbal, J. Arturo Abraldes
article en
1 citations

Abstract

Outdoor fitness equipment (OFE) are strength training installations comparable to those found in indoor gyms but are located outdoors with greater accessibility. However, the scientific evidence supporting their effectiveness remains limited. The objective of this study was to analyze and compare the electromyographic (EMG) activity of upper limb muscle groups during the use of a traditional seated chest press (SCP) machine, a classic OFE SCP (OFE-SCP), and a new OFE-SCP featuring a load selector system (BIOFIT-SCP). The sample was composed of 34 active young men. EMG activity of five muscle groups was analyzed: the anterior deltoid (AD), the clavicular (CP) and sternal (SP) heads of the pectoralis major, and the lateral (LHTB) and long heads of the triceps brachii (LongHTB), under different intensities. The OFE-SCP showed significantly lower EMG activity compared with the SCP and BIOFIT-SCP in all muscles and phases (<i>p</i> < 0.001). Significantly lower EMG activity for the SP in all three phases was found on the BIOFIT-SCP compared with the SCP (<i>p</i> < 0.001), but it was significantly higher for the LHTB and AD in the BIOFIT-SCP compared with the SCP during the full and concentric phases (<i>p</i> < 0.05 to <i>p</i> < 0.001). In conclusion, training with the OFE-SCP generates less EMG activity than traditional machine training, while, in general, BIOFIT-SCP proved effective for strength training comparable to the SCP.

SensorsVol. 24(23)
University of Almería (ES), Universidad Católica de Murcia (ES), Universidad de Murcia (ES)
Ministerio de Ciencia, Innovación y Universidades, Comunidad Autónoma de la Región de Murcia
Openalex Percentile: Top 34%
Sports Performance and Training
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.